Perlick 24

9

Operation & Installation Manual

C-Series (HC24 models)

TOE PLATE INSTALLATION

When the unit is secured in place, install the louvered toe plate. 
Secure  louvered  toe  plate  by  snapping  the  latch  into  the  latch 
catch on the unit. Refer to Figure 7 (below) for Toe Plate Installation 
Illustration  and  Figure  8  (page  10)  for  Toe  Plate  Wood  Overlay 
template.

CAUTION

The louvered toe plate must be removed to service the unit. The 

floor cannot interfere with removal. The louvered sections must 

not be covered or obstructed to prevent proper air circulation.

I

MPORTANT  NOTE:

  To  achieve  maximum  performance,  interior 

louver  openings  and  fan  guard  openings  should  never  be 
obstructed.

SHELVING

Single Door Refrigerator
The single door unit comes standard with  two Industry Exclusive 
full-extension black vinyl-coated pullout shelves.

Single Door Wine Reserve
The  single  door  unit  comes  standard  with  five  full  extension 
black vinyl coated pullout wine racks capable of storing 40 total 
wine  bottles.  Wine  shelves  are  removable  and  adjustable  to 
accommodate oversized (magnum) bottles. Additional storage is 
available on the lower step for an additional five wine bottles.

Single Door Beverage Center
The  single  door  unit  comes  with  two  full-extension  black  vinyl-
coated wine racks and one Industry Exclusive full-extension black 
vinyl-coated  pullout  shelf  allowing  for  storage  of  both  wine  and 
beverages. Shelving positions are adjustable.

Adjusting Full-extension Shelving

1. Pull the shelf out to its farthest position. Locate the tabs in the 

middle of both extenders (Figure 9, below). Lift one tab up 
while pushing the opposite tab down and pull shelf out. 

2. Reposition each bracket separately. Grasp the middle of 

the bracket, pull the front end up and out, then forward to 
remove (Figure 10, below). 

3. Place bracket at the desired position. Push the rear hook into 

the rear key slot. Set front of the bracket on the wall hook. 

4. Repeat for other bracket(s). 

5. Push extenders completely into the unit. Align the shelf 

grooves with the extenders and slide completely into the 
unit. 

Figure 7- Toe Plate Installation

Figure 9- Tab location

Figure 10- Bracket and extender location

Lift one tab up while pushing the 

opposite tab down and pull shelf out

To remove brackets, 

remove shelf, lift front 

of bracket to disengage 

the front key slot, and 

pull forward to disengage

the rear key slot.

Summary of Contents for 24" C-Series

Page 1: ...Luxury Operation Installation Manual C Series HC24 models Form No Z2303 Rev 09 17 2012 HC24RB HC24BB HC24WB ...

Page 2: ......

Page 3: ...ubleshooting section of this manual The information will help you quickly identify a problem and get it remedied In the event you require assistance please contact the dealer where you purchased your unit WARRANTY REGISTRATION CARD To request information or service the model number and serial number must be provided This information is located on the inside ceiling of the unit and on the warranty ...

Page 4: ...lean the condenser every three 3 months can cause the unit to malfunction This could void the warranty Never install the unit behind closed doors Be sure front louvered toe plate is free of obstruction Obstructing the airflow can cause unit to malfunction and may void the warranty CAUTION Use only genuine Perlick replacement parts Imitation parts can damage the unit and may void the warranty INSTA...

Page 5: ...off floor pull out shelf required for clearance 90 Swing 1 3 16 Min clearance from a corner to acheive 90 door swing 1 16 tolerance 24 with 25 3 8 Values may change due to custom pull with a wood overlay door Door Models Figure 1 17 1 4 6 3 16 product ht 5 9 16 Max 3 3 16 8 3 8 10 3 4 Max product ht 10 1 2 6 3 4 10 13 16 Max product ht 7 9 16 50 Area in which electrical outlet must be located J Dw...

Page 6: ...essed into the back wall IMPORTANT NOTE Never use an extension cord to extend the power cord to the electrical receptacle DANGER ELECTROCUTION HAZARD Electrical grounding is required This appliance is equipped with a three prong grounding polarized plug for your protection against possible shock hazards Never remove the round grounding prong from the plug Never use a two prong grounding adapter Ne...

Page 7: ...nti tip brackets and necessary hardware is supplied with the unit The anti tip brackets when properly installed should secure the rear legs and prevent the unit from tipping forward Some installation sites may require modification to provide a secure surface for attaching brackets Refer to Figure 5 right for mounting bracket locations for 24 C Series models IMPORTANT NOTE If installing on a concre...

Page 8: ...TE Leveling legs should not extend more than 3 4 from bottom of the unit 4 Slide cabinet into position Make sure the rear levelling legs slide under the anti tip brackets Push the unit into the open ing until the bottom front edge of the unit is flush with the surrounding cabinetry or until the rear legs are tight against the anti tip brackets 5 Shim the front of the unit so the front face is flus...

Page 9: ...l storage is available on the lower step for an additional five wine bottles Single Door Beverage Center The single door unit comes with two full extension black vinyl coated wine racks and one Industry Exclusive full extension black vinyl coated pullout shelf allowing for storage of both wine and beverages Shelving positions are adjustable Adjusting Full extension Shelving 1 Pull the shelf out to...

Page 10: ...TAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY FORM ELECTRONIC OR MECHANICAL INCLUDING PHOTOCOPYING RECORDING OR USED IN ANYINFORMATION STORAGE TRANSMISSION OR RETRIEVAL SYSTEM WITHOUT WRITTEN PERMISSION FROM THE PERLICK CORPORATION COPYRIGHT 2001 PERLICK CORPORATION ALL RIGHTS RESERVED SHEET 1 OF 4 SCALE TITLE Perlick ...

Page 11: ...ions and are fully interchangable IMPORTANT NOTE Glass with stainless trim and glass with wood trim may sweat in conditions with relative humidity over 75 WOOD OVERLAY INSTALLATION Before beginning installation check all components for proper fit and finish WARNING All overlay doors require a trim panel of at least 3 4 thick The solid wood overlay panel should not weigh more than 20 pounds The gla...

Page 12: ...12 Operation Installation Manual C Series HC24 models Figure 13 Solid wood overlay panel template ...

Page 13: ...13 Operation Installation Manual C Series HC24 models Figure 14 Glass wood overlay panel template ...

Page 14: ...14 Operation Installation Manual C Series HC24 models Figure 15 Wood overlay drawer panel template ...

Page 15: ...15 Operation Installation Manual C Series HC24 models Figure 16 Lock installation solid wood overlay door panel ...

Page 16: ...16 Operation Installation Manual C Series HC24 models Figure 17 Lock installation wood overlay glass door panel ...

Page 17: ...17 Operation Installation Manual C Series HC24 models Figure 18 Lock installation wood overlay drawer panel ...

Page 18: ... of wood overlay panel with handle fastening locations 2 Drill through wood overlay panel at marked locations taking care not to damage the wood overlay panel 3 Countersink screw heads so screw heads are flush with back side of panel Attach handle to overlay panel CAUTION Proper wood working materials and equipment should be used to avoid damage or errors in workmanship 1 With the unit secured in ...

Page 19: ...ature control OFF Turn the adjusting screw completely counterclockwise to the OFF position until a click is heard The condenser fan and motor turns on and off with the compressor CHECKING PRODUCT TEMPERATURE To accurately check the temperature of product stored in the refrigerated compartment insert an accurate thermometer into a plastic non breakable bottle partially filled with water Tighten the...

Page 20: ... remedy before calling for service The problem could be something which can be solved without a service call DANGER NEVER ATTEMPT TO REPAIR OR PERFORM MAINTENANCE ON THE UNIT UNTIL THE MAIN ELECTRICAL POWER HAS BEEN DISCONNECTED Problem No interior light Is the bulb loose Is the bulb burnt out Problem Light stays on when door is closed Manual ON OFF light switch is turned ON Is the door switch mak...

Page 21: ...On hot days and in warm room temperatures the system will run longer Problem Condensation forms inside the refrigerated compartments This is normal during high humidity and frequent door openings Are the doors closing and sealing properly Problem Condensation forms on the outside of the unit During periods of high humidity some condensation might appear on outside surfaces The condensation will di...

Page 22: ... United States the District of Columbia or the ten provinces of Canada All service provided by Perlick Corporation under the above warranty must be performed by authorized Perlick service representatives unless otherwise specified by Perlick Service will be provided in the home during normal business hours This warranty applies only to products installed for normal residential use it does not incl...

Page 23: ...soever for any incidental consequential or special damages arising from the sale use or installation of the product or from any other causes whatsoever whether based on warranty expressed or implied or otherwise based on contract tort or any other theory of liability Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequen...

Reviews: