Perle SMI Media Converter Guide
17
MCR-MGT “PWR” LED is RED
•
The MCR-MGT module is defective. It will need to be
replaced.
MCR-MGT “PWR” LED is Blinking Green
The MCR-MGT module is in the process of booting up. If this
state persists for longer then one minute, reset the module by
momentarily pressing the reset switch on the front of the module.
See
Front view – reset switch
.
Cannot connect serially to MCR-MGT Modul
e
•
Make sure that the PWR LED is “Green”
•
Ensure that you are using the right cable/adapter.
•
If you see garbage characters, the baud rate of the serial
port may have been changed from the original 9600
baud. Configure your terminal emulation to match
configured speed.
•
If you don’t know what the speed is, you could reset the
module to “factory default” by pressing and holding the
reset switch ( 3 seconds) on the front of the MCR-MGT
module. NOTE, this will erase all of the configuration
back to a factory default state.
Cannot connect to MCR-MGT Module using IP
•
Make sure that the PWR LED is “Green”
•
Make sure that the LCK LED is “Green”. (Copper link
connection is up).
•
Make sure you are using the IP address which is
configured on the MCR-MGT module.
•
If you don’t know what the IP address is, you can use
the “SetIP” utility provided on the CD to display the IP
address of all units on your LAN segment.