Perle S-1110-XT Installation Manual Download Page 10

 Perle 10/100/1000 Ethernet Extended Temperature Media Converter  

 Installation Guide

  

 

10

 

 

 

Installing the Simplex Fiber Cable 

1.  Locate a 1000Base-X compliant simplex (1 strand) fiber cable 

with appropriate connectors. Ensure that the TX wavelength 
matches the RX wavelength at the other end and the RX 
wavelength matches the TX wavelength at the other end. 

2.  Connect the fiber cable from one media converter to the other 

media converter/switch/fiber device. 

 

Installing the Copper Cable 

1.  Locate 10/100/1000Base-T compliant copper cables with the 

appropriate connectors. 

2.  Connect the RJ-45 cable between the Perle media converter 

and the device.  

Note: The Perle media converter supports Auto-MDIX which 
allows connection of a straight-through or cross-over Ethernet 
cable. See 

Auto-MDIX Jumper Settings

 in this guide for jumper 

positions. 

Grounding the Media Converter 

If your installation requires additional grounding this procedure can 
be followed. 

Grounding the chassis requires the following items: 

 

One grounding lug (not provided). 

 

Grounding wire 12 to 18 AWG (not provided).  

 

Cross-head screwdriver (not provided). 

Note: For your safety, when installing this equipment, always 
ensure that the chassis ground connection is installed first and 
disconnected last. 

Summary of Contents for S-1110-XT

Page 1: ...P N 5500321 10 Perle10 100 1000 Ethernet Extended Temperature Media Converters Installation Guide S 1110 XT ...

Page 2: ...her single mode SM or multimode MM and can operate over different wavelengths and distances depending on the model selected see table below Extended Temperature Models Model Connector xx Mode Distance Wavelength TX RX S 1110 M2xx05 XT SC ST MM 550 m 1804 ft 850 nm S 1110 S2xx10 XT SC ST SM 10 km 6 2 mi 1310 nm S 1110 S1SC10U XT SC SM 10 km 6 2 mi 1310 1490 nm S 1110 S1SC10D XT SC SM 10 km 6 2 mi 1...

Page 3: ...le s 6 Install and connect the copper cable s 7 Power up the media converter Auto MDIX Jumper Settings Note The factory settings for Auto MDIX will work for most installations but in the rare case that you need to modify the settings the procedure is below To access the Auto MDIX jumper settings unscrew the six side screws on the case and remove the cover plate Locate the MDIX AUTO jumper set as d...

Page 4: ...ng in the side of the enclosure Note All switch changes take effect immediately DIP Switch Settings Auto Negotiation copper Switch 1 Switch Position Copper Up default Auto Down Off Note Auto negotiation should only be turned off if the copper link partner does not support Auto Negotiation and fixed settings are required by the copper link partner ...

Page 5: ...media converter will be determined by the Duplex switch 4 and Speed switch 5 DIP switch settings Link Mode Switch 2 Switch Position Mode Up default Standard Mode Down Smart Link Pass Through Standard Mode In this mode link on the fiber and copper sides can be brought up and down independently of each other A loss of link on either the fiber or copper port can occur without affecting the other conn...

Page 6: ... media converter is set up for Fiber Fault Alert FFA and the local media converter is set up with Link Pass Through a loss of fiber link will be passed through to the local copper connection thus notifying the connected device If the media converter has been set to Smart Link Pass Through mode the effect will be the same as FFA since the link loss on the fiber receiver will result in bringing down...

Page 7: ...nnection on its receiver 2 A Sends FFA 3 B Detects FFA signal and shuts down the fiber link 4 B Drops link on copper connection because Smart Link Pass Through is configured 5 A Link on copper connection is not affected because Smart Link Mode is set to Standard Duplex copper Switch 4 Switch Position Copper port Up default Full Duplex Down Half Duplex Note When Auto Negotiation SW1 is set to Off t...

Page 8: ... Switch Position Fiber 1000 Mbps Up default Auto Down Off Auto The Media Converter will negotiate Ethernet parameters on the fiber connection This will ensure that the most optimal connection parameters will be in effect If connecting to another Perle Media Converter this parameter should be set to Auto The Media Converter Module will advertise 1000Mbps Full and Half Duplex no Pause Off The Media ...

Page 9: ...power to the powered devices will be maintained This mode will override all other switch settings Installing the SFP Fiber Module SFP models only 1 Locate the appropriate fiber module and insert the SFP into the opening on the front of the media converter 2 Ensure the SFP module is properly seated The release latch of the SPF fiber transceiver must be in the closed up position before insertion 3 T...

Page 10: ...er cables with the appropriate connectors 2 Connect the RJ 45 cable between the Perle media converter and the device Note The Perle media converter supports Auto MDIX which allows connection of a straight through or cross over Ethernet cable See Auto MDIX Jumper Settings in this guide for jumper positions Grounding the Media Converter If your installation requires additional grounding this procedu...

Page 11: ...k from the Media Converter Ensure the Power Source is off Strip both wires 5mm 3 16 th inch Loosen the terminal block screws and connect Positive wire to the left terminal Connect the Negative wire to the right terminal Tighten Terminal screws 0 22Nm 0 25Nm torque Plug the terminal block into the Media Converter Turn on power source Check that the PWR LED light is lit For extra power cable strain ...

Page 12: ...iber interfaces are in loopback mode Blinking fast Power On failure See LED Pattern to determine pattern combination and failure cause LED Pattern FDF LKF FDC PSE Off Off On On SFP incompatible All other LED patterns Internal hardware failure FDF Fiber Duplex On Full Duplex Off Half Duplex LKF Status on Fiber Link On Fiber link is present Off No fiber link present Blinking slow Fiber link appears ...

Page 13: ...ough Blinking fast Copper link up and receiving data Troubleshooting General 1 Ensure power source is connected 2 Ensure the remote device s fiber connection type is compatible with the media converter If using a simplex fiber connection ensure that you have both an Upstream U and Downstream D media converter 3 Ensure all cabling is of the correct type and is in good working order 4 For duplex fib...

Page 14: ...iguration Connect the power source to the Media converter Method 2 The fiber connection can also be verified by configuring the remote media converter for loopback mode The LKF LEDs on both media converters should be lit Data should pass through the local converter over the fiber connection to the remote media converter At the remote media converter the data will be looped back and passed through ...

Page 15: ... SM TX 1490 RX 1310 Min 9 Max 3 Min 20 Max 3 11 S 1110 SFP XT SFP Note 1 Note 1 Fiber characteristics will depend on the SFP fiber module selected It is recommended the SFP fiber modules used with this product are rated for ambient temperature 40 C to 85 C 4 0 F to 185 F Fiber Cabling Requirements MM 50 125 microns or 62 5 125 microns SM 9 125 microns Ethernet Copper Cabling Requirements Category ...

Page 16: ...measures EN 55024 Class A Laser Safety IEC 60825 1 2007 This product meets Class I Laser safety requirements per IEC 60825 1 2007 standard and complies with FDA CDRH 21 CFR1040 10 and 21CFR1040 11 WARNING Visible and invisible laser radiation may be present when cables are not connected Do not stare into the beam or view the beam directly with optical instruments Failure to observe this warning co...

Reviews: