background image

Part# 5500434-10 (Rev G) 

 

Perle S-10GR-STS 

Media Converter 

 

Installation Guide 

Summary of Contents for S-10GR-STS

Page 1: ...Part 5500434 10 Rev G Perle S 10GR STS Media Converter Installation Guide...

Page 2: ...ems or third party MSA compatible 10G 2 5G 1G SFP modules See the Technical Specifications section in this guide for supported modules Visit Perle s web site for the most up to date Installation guide...

Page 3: ...Perle Standalone S10 GR STS Installation Guide 3 Front View...

Page 4: ...tting all switches in the UP position will work for most installations These are the steps required to configure the S 10GR STS media converter 1 Set the DIP switch settings optional 2 Insert the appr...

Page 5: ...reflected through the media converter to the other port connection If link is lost on one of the connections then the other link will be brought down by the media converter Standard In this mode the l...

Page 6: ...Standard Mode Fiber Fault Alert Media Converter B Configuration Link Mode Smart Link Pass through Mode Fiber Fault Alert Sequence of Events 1 Media Converter A loses fiber connection RX 2 Media Conve...

Page 7: ...plex mode Fiber Interface Lookback Switch 4 Switch Position Mode Up default Disabled Down Enabled Enabled When enabled the media converter will be in fiber loopback mode Disabled When disabled the med...

Page 8: ...Converter has 1000 Mbps SGMII interface support on port 1 To set the jumper remove the screws from the sides of the unit then remove the lid The SGMII jumper is located on the outer edge at the midpoi...

Page 9: ...ration mode Green blinking slowly the module is in test or loopback mode Red Solid During power up Hardware error detected See PWR Red LED Errors Red Blinking quickly Error detected See LK1 LK2 Errors...

Page 10: ...de 10 Off No fiber link present LK2 Port 2 Activity On Fiber link present Blinking quickly Fiber link present and receiving data Blinking slowly The fiber link has been taken down as a result of Smart...

Page 11: ...e SFP SFP On On Internal Error Off On Mismatch in Cut though mode On Off SFP SFP communication error PWR Red LED Errors LK1 LK2 Meaning Blinking Blinking Blinking one second on 3 seconds off the maxim...

Page 12: ...he chassis requires the following items One grounding lug not provided One 18 12 AWG wire not provided Note For your safety when installing this equipment always ensure that the chassis ground connect...

Page 13: ...S Installation Guide 13 Attaching the Power Cord Strain Relief Clip 1 Feed the power cord through the opening in the power cord relief clip 2 Attach the power cord relief clip to the chassis and secur...

Page 14: ...P SPF modules are properly seated 3 Proceed with fiber cable connections Installing the Duplex Fiber Cable 1 Locate a 1000 10GBase X compliant duplex 2 strands fiber cable with appropriate connectors...

Page 15: ...up and then turn off It will only come on when the temperature inside the case becomes elevated If the module is operating above its specified maximum operating temperature the S 10GR STS will reduce...

Page 16: ...able 10G Fiber Transceivers Power levels 1 and 2 EEE 802 3ae 10G Base R 10 Gigabit SFP slot support 10GBase R Standard SFP Power level 1 1 watt and level 2 1 5 watts as per SFP 8431 Operating Temperat...

Page 17: ...0GBase LMR 10GBase LR 10GBase ER 10GBase ZR CWDM DWDMBase Supported 10 Gigabit Copper pluggable transceivers SFP Direct Attach Cable DAC Also known as Twinax 10GBase CU 10GSFP Cu 10GBase CX1 10GBase C...

Page 18: ...STS Installation Guide 18 Fiber Cabling Requirements MM 50 125 microns or 62 5 125 microns SM 9 125 microns Note Please refer the product page on the Perle website for the most up to date specificati...

Page 19: ...P modules are inserted correctly into the transceiver ports No connectivity Set all DIP switches to the UP position Loopback Mode The media converter can be put into Loopback mode for diagnosis purpos...

Page 20: ...se the user will be required to correct the interference at his her own expense EN 55032 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interference i...