Page 1: ...P N 5500300 19 Perle Gigabit Media Converters Installation Guide S 1000 XXXXXX S 1000 SFP...
Page 2: ...SM 10 km 6 2 mi 1310 1490 nm S 1000 S1SC10D SC SM 10 km 6 2 mi 1490 1310 nm S 1000 S1SC20U SC SM 20 km 12 4 mi 1310 1490 nm S 1000 S1SC20D SC SM 20 km 12 4 mi 1490 1310 nm S 1000 S2xx40 SC ST LC SM 4...
Page 3: ...and connect the fiber cable Install and connect the copper cable Power up the media converter The default switch settings all switches in the UP position will work for most installations DIP Switches...
Page 4: ...The parameters used in this negotiation by the media converter will be determined by the Duplex switch 4 and Pause switch 5 switch settings Link Mode Switch 2 Switch Position Mode Up default Standard...
Page 5: ...l This in effect notifies the fiber link partner that an error condition exists on the fiber connection If the remote media converter is set up for Fiber Fault Alert FFA Enabled and the local media co...
Page 6: ...on Mode Up default Auto Down Half Auto When Fiber Negotiation has been turned off SW 1 the media converter will use this Duplex setting for its Ethernet parameter negotiation on the copper connection...
Page 7: ...hrough to the end device This switch setting is provided so that the attached device near end can negotiate its Ethernet parameters as if it was negotiating directly with the far end device The Pause...
Page 8: ...ber Cable Locate a 1000Base X compliant duplex 2 strands fiber cable with male connections Connect the fiber cables from one media converter to the other media converter switch fiber device ensuring t...
Page 9: ...nd the device Note The Perle media converter supports Auto MDI X either a straight through or cross over Ethernet cable may be used Powering up the Perle Media Converter 1 Connect the Perle supplied p...
Page 10: ...it is in loopback mode Blinking quickly the unit has a hardware error LKF Fiber Link Activity On Fiber link present Blinking quickly Fiber link present and receiving data Blinking slowly Fiber link di...
Page 11: ...ht through or crossover and automatically configures the connection The media converter can also correct for wires swapped within a pair Error Recovery In certain configurations and under specific con...
Page 12: ...f Fiber Negotiation SW1 Down on both media converters Leave all other switches UP 2 Connect the near end device to the copper connection The LKC LED indicates good copper connection If the LKC LED is...
Page 13: ...nsions 80 mm x 120 mm x 26 mm Fiber Optic Specifications Model Mode Wavelength nm TX Power dB RX Power dB Budget dB S 1000 M2xx05 MM TX 850 RX 850 Min 9 5 Max 4 Min 17 Max 3 7 5 S 1000 M2xx2 MM TX 131...
Page 14: ...0 Min 0 Max 5 Min 32 Max 9 32 S 1000 S1SC120U SM TX 1510 RX 1590 Min 3 Max 2 Min 34 Max 9 31 S 1000 S1SC120D SM TX 1590 RX 1510 Min 3 Max 2 Min 34 Max 9 31 S 1000 S2xx160 SM TX 1550 RX 1550 Min 2 Max...
Page 15: ...ase the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interference...
Page 16: ...http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Support Qu...