Perle 10/100/1000 Ethernet Extender Modules 

 Dip Switches 

The Dip switches are accessible through the opening in the side 
of the enclosure

 

NOTE:

 

All switch changes take effect immediately and will 

result in a link reset on both the Line and the Ethernet ports. 

Dip Switch Settings 

Auto Local (CO) / Remote (CPE) (Switch 1) 

Switch Position 

Mode 

On (Default) 

Auto Local 

Off 

Remote 

NOTE: Ethernet Extender modules work in pairs. One side of 
the link must be set to Local / CO and the other end of the 
link must be set to Remote / CPE. 

Summary of Contents for eX-1C/CM110-BNC

Page 1: ...Perle 10 100 1000 Ethernet Extender Modules 10 100 10 100 1000 Gigabit eX 1C CM110 RJ eX 1C CM1110 RJ eX 1C CM110 BNC eX 1C CM1110 BNC eX 1C CM110 TB eX 1C CM1110 TB Part 5500331 11 ...

Page 2: ...ese Ethernet Extender modules enable Ethernet communication across a single pair of copper wires such as 2 wire twisted pair telephone wire or coax cable using VDSL2 technology They extend Ethernet beyond the 328 foot 100 meter limitation up to 3 kilometres 1 86 miles Models can be ordered with an RJ 45 BNC or Terminal Block connector Getting to know your eX C CM110 eX C CM1110 Module Front View ...

Page 3: ...for Remote mode CPE These are the steps required to configure a pair of Perle Ethernet Extender Modules 1 Obtain a pair of Perle Ethernet Extender modules and a pair of Perle Media converter chassis 2 Set the Dip switch settings on each Ethernet Extender module optional 3 Install the modules in the chassis See Installing Modules for more information 4 Connect a Line cables to the port labelled as ...

Page 4: ...changes take effect immediately and will result in a link reset on both the Line and the Ethernet ports Dip Switch Settings Auto Local CO Remote CPE Switch 1 Switch Position Mode On Default Auto Local Off Remote NOTE Ethernet Extender modules work in pairs One side of the link must be set to Local CO and the other end of the link must be set to Remote CPE ...

Page 5: ...tion Mode Up default High Speed Down Long Range High Speed In this mode the VDSL connection will be optimized for speed and the effective bidirectional data rate will be up to 100 mbps in each direction This setting also enables VDSL Fast Mode Long Range In this mode the VDSL connection will be optimized for distance and the achievable distance will be up to 3 km NOTE The actual distance and rates...

Page 6: ...ut may result in slower speeds Signal to noise ratio 9dB This setting is recommended if Rate switch 2 has been set to High Speed Signal to noise ratio 6dB This setting is recommended if Rate Switch 2 has been set to Long Range Line Loopback Switch 5 Switch Position Mode Up default Loopback mode off Down Loopback mode on Line Loopback Mode off The Line loopback feature is off This is default positi...

Page 7: ...0 Mbps for eX 1C1110 models full and half duplex as well as pause and remote fault capabilities to the link partner Ethernet AutoNeg Off When the Auto Negotiation switch is set to the OFF position the Ethernet Extender will not negotiate the Ethernet parameters with the Ethernet link partner The parameters used by the Ethernet Extender will be determined by the Ethernet Speed Switch 7 and Ethernet...

Page 8: ...et Extender module will not pass the state of the Ethernet interface across the Line connection to its peer A loss on the Ethernet interface can occur without affecting the peer connection Link Pass Through In this mode the Ethernet Extender will pass the state of the Ethernet interface across the Line connection to its peer If link is lost on the Ethernet connection then the peer Ethernet connect...

Page 9: ...t Standard Mode Down Interlink Fault Feedback Standard Mode The status of the VDSL interface will not be passed to its Ethernet interface Interlink Fault Feedback The status of the VDSL interface will be passed to its Ethernet interface If the VDSL line link is lost the Ethernet link will be brought down Interlink Fault Feedback The 10 100 1000 ports LNK on each of the links will be turned off if ...

Page 10: ...arge precautions when installing or removing the module s from the Chassis Failure to observe this caution could result in damage to the module s and or chassis Connecting to the Ethernet Port 1 Locate Gigabit or 10 100Base T compliant copper cables with male RJ 45 connectors installed at both ends 2 Connect the RJ 45 cable directly to the RJ 45 port labelled ETHERNET on the front of the Ethernet ...

Page 11: ...with a Terminal Block Connector 1 Strip insulator sheathing from both wires 5mm 3 16 th inch to expose copper conductor wire 2 Loosen the terminal block screws and connect one wire to the left terminal Connect the other wire to the right terminal Tighten the terminal screws 0 22Nm 0 25Nm torque NOTE Refer to the Technical Specifications section at the back of this guide for pin cabling requirement...

Page 12: ...ode Off Unit is configured for RMT CPE mode Note In Auto Local mode the Ethernet Extender module may switch roles in order to connect with a peer The Local Remote LEDs will reflect the current mode role PWR On Power is applied to the unit Blinking slow The unit is in Loopback mode Blinking fast The unit has a hardware failure Off No Power to the unit ETH On Link detected Off No Link detected Blink...

Page 13: ...UP position this procedure is recommended for troubleshooting Check Ethernet Connection 1 Ensure Link mode SW9 and Interlink Fault Feedback SW10 are set to the UP position on both Ethernet Extenders 2 Connect the near end device to an Ethernet hub or device The ETHERNET LED should be lit to indicate a good connection If the ETHERNET LED is not lit then check the Ethernet cable and the attached dev...

Page 14: ... 73 lbs Dimensions 203 x 38 x 152mm 8 x1 5 x 6 inches Operating Temperature 0 C to 50 C 32 F to 122 F Storage Temperature 25 C to 70 C 13 F to 158 F Ethernet Copper Cabling Requirements Category 5 UTP or STP 24 22 AWG Straight through or Ethernet crossover VDSL Interfaces RJ 45 Connector BNC Connector Pin Signal Block Terminal Connector 1 No connection 2 No connection 3 No connection 4 Ring 5 Tip ...

Page 15: ...anty coverage Details can be found at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Support Query may be made via this web page http www perle com support_services support_request shtml Copyright 2013 Perle Systems Limited All rights reserved No part of th...

Reviews: