Perle 10/100 Media Converter Module – Installation Guide

  

 

Auto-Config Jumper (CM-110 only) 
 

The Auto-Config jumper (J6) is located just below the Auto-MDIX 
jumper (see above). Refer to the diagram below for labelling. This 
jumper only applies to CM-110 modules.  

Strapping pins 1 and 2 of the jumper will set the module in SW mode 
and strapping pins 2 and 3 will set it in Auto Config mode. 

Auto: When set to Auto the module will, at power-up, check its 
internal flash memory to see if configuration information has been 
downloaded to it from a management module. If so it will use this as 
its running configuration. If there is no configuration in flash it will read 
the settings of the DIP switches and use those as its running 
configuration. 

SW: When set to SW (Switch), the module will, at power-up, read the 
settings of the DIP Switches and use those as its running 
configuration. It will ignore any configuration information in its flash 
memory. 

NOTE: The default jumper setting is Auto 

 

Summary of Contents for C-110-M2ST2

Page 1: ...P N 5500307 15 Perle 10 100 Ethernet Media Converter Module Installation Guide C 110 XXXXX Unmanaged Module CM 110 XXXXX Managed Module...

Page 2: ...formation on management features of the CM 110 module refer to the MCR MGT Module User s Guide Model Connector Mode Distance Wavelength C 110 M2ST2 CM 110 M2ST2 SC ST LC MM 2 km 1 2 mi 1310 nm C 110 S...

Page 3: ...a Converter Module into the Chassis 5 Connect the fiber cable 6 Connect the copper cable Auto MDIX Jumper Note The factory settings for Auto MDIX will work for most installations but if there is a nee...

Page 4: ...When set to Auto the module will at power up check its internal flash memory to see if configuration information has been downloaded to it from a management module If so it will use this as its runni...

Page 5: ...operation the Media Converter Module will negotiate Ethernet parameters on the copper connection This will ensure that the most optimal connection parameters will be used If the copper link partner d...

Page 6: ...agate through both Converters and will result in a loss of copper link at the near end device This would in effect resemble a direct copper connection Standard Mode In this mode the links on the fiber...

Page 7: ...or detect the FEF signal then the FEF switch needs to be set Disabled The Media Converter Module will not monitor for or generate Far End Fault The following diagram is an illustration of the operati...

Page 8: ...connection Up The Media Converter Module will be set to Full Duplex mode Down The Media Converter Module will be set to Half Duplex mode Speed copper Switch 5 Switch Position Mode Up default 100 Down...

Page 9: ...h 7 Switch Position Mode Up default Disabled Down Enabled Disabled This is the setting for normal operation The switch must be set to this position in order for data to pass through the Media Converte...

Page 10: ...ia Converter Module from its packaging 2 Using a cross head screwdriver remove the screw holding the face plate to the Chassis to reveal the slot opening 3 Set the jumpers and DIP switches on the Medi...

Page 11: ...ntly pull the Media Converter Module out 2 If not inserting a replacement cover the opened slot with a face plate and secure the screw Installing the Duplex Fiber Cable Locate a 100Base X compliant du...

Page 12: ...nstalling the Copper Cable Locate 10 100Base T compliant copper cables with male RJ 45 connectors installed at both ends Connect the RJ 45 cable between the Perle Media Converter Module and the device...

Page 13: ...dule is in Loopback mode Blinking fast The module has a hardware failure FDF fiber On Full Duplex Mode Off Half Duplex Mode LKF fiber On The fiber link is present Off No fiber link is present Blinking...

Page 14: ...e Media Converter Module brings down a link to convey status there is potential for a deadlock Recovery is achieved by momentarily restoring the link to see if the original failure has been resolved I...

Page 15: ...If unable to get full connectivity with all DIP switches in the UP position these methods are recommended for troubleshooting Method 1 1 If the Module is a CM 110 set the Auto Config jumper J6 to SW s...

Page 16: ...Converters should be lit Data should pass through the local converter over the fiber connection to the remote Media Converter At the remote Media Converter the data will be looped back and passed thro...

Page 17: ...1 C 110 M2LC2 CM 110 M2LC2 MM TX 1310 RX 1310 Min 20 Max 12 Min 30 Max 14 10 C 110 S2SC20 CM 110 S2SC20 SM TX 1310 RX 1310 Min 18 Max 7 Min 32 Max 3 14 C 110 S2ST20 CM 110 S2ST20 SM TX 1310 RX 1310 Mi...

Page 18: ...TX 1550 RX 1310 Min 14 Max 8 Min 32 Max 3 18 C 110 S1SC40U CM 110 S1SC40U SM TX 1310 RX 1550 Min 8 Max 3 Min 33 Max 3 25 C 110 S1SC40D CM 110 S1SC40D SM TX 1550 RX 1310 Min 8 Max 3 Min 33 Max 3 25 Fib...

Page 19: ...hich case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interfe...

Page 20: ...t http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Support...

Reviews: