Perle 05062440 Installation Manual Download Page 15

Gigabit Fiber to Fiber Media Converter Module – Installation Guide

    

15 

Compliance Information  

  FCC 

This product has been found to comply with the limits for a Class A digital device, 
pursuant to Part 15 of the FCC rules. These limits are designed to provide 
reasonable protection against harmful interference when the equipment is operated 
in a commercial environment. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with the 
instructions in this Guide, may cause harmful interference to radio communications. 
Operation of this equipment in a residential area is likely to cause harmful 
interference, in which case the user will be required to correct the interference at 
his/her own expense. 

EN 55022, Class A,  

WARNING

 

This is a Class A product. In a domestic environment this product may 

cause radio interference in which case the user may be required to take adequate 
measures. 

EN 55024, Class A 

Laser Safety – IEC 60825-1:2007 

This product meets Class I Laser safety requirements per IEC-60825-1:2007 
standard and complies with FDA/CDRH  21 CFR1040.10 and 21 CFR1040.11. 
WARNING: Visible and invisible laser radiation may be present when cables are 
not connected. Do not stare into the beam or view the beam directly with optical 
instruments. Failure to observe this warning could result in an eye injury or 
blindness. 
WARNING: Use of controls, adjustments or the performance of procedures other 
than those specified herein may result in hazardous radiation exposure. 

Summary of Contents for 05062440

Page 1: ...P N 5500315 11 Rev A Perle Gigabit Fiber to Fiber Media Converter Module Installation Guide C 1000MM XXXXXX Unmanaged Module CM 1000MM XXXXXX Managed Module...

Page 2: ...SM Multimode to Single Mode Single Strand MM The first fiber port will be multimode MM and the second fiber port can be either single mode SM or multimode MM depending on the model selected They can o...

Page 3: ...0 km 12 4 mi 1310 1490 nm C 1000MM S1SC20D CM 1000MM S1SC20D SC SM 20 km 12 4 mi 1490 1310 nm C 1000MM S1SC40U CM 1000MM S1SC40U SC SM 40 km 25 mi 1310 1490 nm C 1000MM S1SC40D CM 1000MM S1SC40D SC SM...

Page 4: ...3 Insert the Media Converter Module into the chassis 4 Connect the fiber cables Auto Config Jumper CM 1000MM only The Auto Config jumper is J5 Refer to the diagram below for labelling Auto Pin 2 and P...

Page 5: ...nverter will negotiate fiber parameters on both MM1 and MM2 SM2 fiber ports This will ensure the most optimal connection parameters will be in effect If connecting to another Perle media converter thi...

Page 6: ...Up default Enabled Down Disabled Enabled If the media converter module detects a loss of fiber signal on the fiber receiver the media module will immediately disable its fiber transmitter signal on t...

Page 7: ...verter B Configuration Link Mode Smart Link Pass Through Mode Fiber Fault Alert Sequence of Events 1 Media Converter A loses fiber connection RX on MM2 SM2 2 Media Converter A disables the transmitter...

Page 8: ...ive RX fiber connection is looped back to the transmit TX fiber connection Note Only one fiber interface can be in loopback at a time Remote Loopback Fiber 2 Switch 5 Switch Position Mode Up default D...

Page 9: ...slot opening 3 Set the jumpers and DIP switches on the Media Converter Module to the desired operating mode optional 4 Locate the top and bottom alignment guides inside the MCR Chassis 5 Using the mo...

Page 10: ...te and secure the screw Installing the Duplex Fiber Cable 1 Locate a 1000Base X compliant duplex 2 strands fiber cable with appropriate connectors 2 Connect the fiber cables from one Converter to the...

Page 11: ...n loopback mode Blinking quickly the module has a hardware error LK1 MM1 Fiber Link10 Activity On Fiber link present Blinking quickly Fiber link present and receiving data Blinking slowly The fiber li...

Page 12: ...he UP position these methods are recommended for troubleshooting Method 1 1 Turn off Fiber Negotiation SW1 Down on both media converters Leave all other switches UP 2 Connect the near end device to po...

Page 13: ...X Power dB RX Power dB Budget dB C 1000MM M2SC05 CM 1000MM M2SC05 MM TX 850 RX 850 Min 9 5 Max 4 Min 17 Max 3 7 5 Model Mode Wave length nm TX Power dB RX Power dB Budget dB C 1000MM M2xx05 CM 1000MM...

Page 14: ...x 3 Min 20 Max 3 11 C 1000MM S1SC20U CM 1000MM S1SC20U SM TX 1310 RX 1490 Min 8 Max 3 Min 22 Max 3 14 C 1000MM S1SC20D CM 1000MM S1SC20D SM TX 1490 RX 1310 Min 8 Max 3 Min 22 Max 3 14 C 1000MM S1SC40U...

Page 15: ...in which case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio in...

Page 16: ...e found at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical...

Reviews: