2.
If necessary, remove breather pipes on cover (6).
Remove nuts (7) and remove cover (6) from
housing (1).
3.
Remove circlip (4) and remove the breather
element (3) and discard.
4.
Remove the O ring seal (5) from the cover.
Install the Breather Element
Ensure that all the components are clean and free
from damage.
Illustration 56
g02827300
Typical example
(A) Diameter
(B) Diameter
1.
Install a new O ring seal (5) onto the cover (6).
Note:
The breather element must have the correct
orientation before installation. Diameter (A) is visibly
larger than diameter (B).
2.
Install diameter (A) of the breather element (3)
onto the shaft (2). When correctly installed the part
number of the breather element will be visible.
3.
Install circlip (4) and cover (6). Install nuts (7) and
tighten to 25 N·m (18 lb ft). If necessary, install
breather pipes to cover.
4.
Install the guard, refer to OEM.
i07819538
Engine
Mounts
-
Inspect
Note:
The
engine
mounts
may
not
have
been
supplied
by
Perkins.
Refer
to
the
Original
Equipment
Manufacturer
(OEM)
information
for
further
details
on
the
engine
mounts
and
the
correct
bolt
torque.
Inspect
the
engine
mounts
for
deterioration
and
for
correct
bolt
torque.
Excessive
engine
vibration
can
be
caused
by
the
following
conditions:
• Incorrect mounting of the engine
• Deterioration of the engine mounts
• Loose engine mounts
Any engine mount that shows deterioration should be
replaced. Refer to the OEM information for the
recommended torques.
When the engine mounts are supplied by Perkins the
maintenance procedure will be supplied in the
Disassembly and Assembly manual for your engine.
i04728471
Engine
Oil
Level
-
Check
Hot oil and hot components can cause personal
injury. Do not allow hot oil or hot components to
contact the skin.
Illustration 57
g02829378
Typical example
100