8. Remove the press flange and connections from the pump housing
9. Remove the pump hose to be exchanged
Fitting pump hose
1. Clean the interior surfaces of the pump housing
2. Check the rollers. Ensure that the roller surfaces are not damaged
3. Fit the hose into the pump casing
4. Fit the connections into the hose
5. Fasten the press flange and the connections to the pump casing, tightening progressive the bolts
in clock wise (1, 2, 3, 4, 1, 2, 3, 4,
etc…), until the flange becomes totally tighten.
6. Replace the front cover
7. Turn the rotor ½ revolution with the help of the motor so that the remaining roller presses against
the pump hose
8. Remove the front cover
9. Fit the second roller into the pump rotor
10. Fill the lubricant until the lubricant level has risen above the level line in the lubricant level
window installed at the bottom of the front cover.
11. Replace and tighten the front cover to the pump housing
13. Mount the pipes from both discharge and suction sides
14. Open all of the valves