This Wet/Dry Vac is double-insulated, eliminating the need for a separate grounding system. Use only 

identical replacements parts. Read the instructions for Servicing Double-Insulated Wet/Dry Vacs before 

servicing.  Use this Wet/Dry Vac as described in this manual. 

Observe the following warnings that appear on the motor housing of your Wet/Dry Vac.

 

 

DOUBLE INSULATED - GROUNDING NOT REQUIRED - WHEN SERVICING USE ONLY 

 

IDENTICAL REPLACEMENT PARTS.

 

 

WARNING: 

TO REDUCE THE RISK OF ELECTRIC SHOCK-DO NOT EXPOSE TO RAIN.  STORE 

INDOORS.

 

 

WARNING: 

 FOR YOUR OWN SAFETY, READ AND UNDERSTAND OPERATOR’S MANUAL. DO 

NOT RUN UNATTENDED.  DO NOT PICK UP HOT ASHES, COALS, TOXIC, FLAMMABLE OR OTHER 

HAZARDOUS MATERIALS, DO NOT USE AROUND EXPLOSIVE LIQUIDS OR VAPORS.

 

 

CAUTION:

 

• Do not vacuum drywall dust, cold fireplace soot or cold ash with washable Wet/Dry filter only. This is very 

fine dust which will not be captured by the filter and may cause damage to motor. When vacuuming fine dust 

use the 

washable cartridge filter

 and the fine dust collection bag.

 

 

WARNING: 

 

SERVICING OF DOUBLE-INSULATED WET/DRY VACUUMM

 

WITH A DOUBLE-INSULATED WET/DRY VACUUM, TWO SYSTEMS OF INSULATION ARE PROVIDED 

INSTEAD OF GROUNDING. NO GROUNDING MEANS IS PROVIDED ON A DOUBLE-INSULATED 

APPLIANCE, NOR SHOULD A MEANS FOR GROUNDING BE ADDED. SERVICING A DOUBLE 

INSULATED WET/DRY VACUUM REQUIRES EXTREME CARE AND KNOWLEDGE OF THE SYSTEM, 

AND SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSONNEL. REPLACEMENT PARTS FOR 

A DOUBLE-INSULATED WET/DRY VACUUM MUST BE IDENTICAL TO THE PARTS THEY REPLACE. 

YOUR DOUBLE-INSULATED WET/DRY VAC IS MARKED WITH THE WORDS ‘DOUBLE INSULATED’ 

AND THE SYMBOL         (SQUARE WITHIN A SQUARE) MAY ALSO BE MARKED ON THE 

APPLIANCE.

 

 

• To reduce the risk of electric shock-unplug before cleaning or servicing. 

• DO NOT use the vacuum cleaner without filters in place.

 

CAUTION:

 TO REDUCE THE RISK OF INJURY FROM MOVING PARTS- UNPLUG BEFORE SERVICING. 

 

 

 

 

When using an extension cord with your Wet/Dry Vac refer to the following table to determine the required 

A.W.G. wire size.  Before using the cleaner make sure the power cord and extension cord are in good 

working conditions. Make repairs or replacements before using the vacuum cleaner.  Only use extension 

cords that are rated for outdoor use. 

 

 

 

 

 

 

 

 

 

 

Length of Extension Cord 

110V-120V 

25 Feet  

7.5 Meters 

50 Feet   

15.25 Meters 

100 Feet  

30.5 Meters 

150 Feet  

45.7 Meters 

Amps 

A.W.G Wire Size 

0-6 

18 

16 

16 

14 

7-10 

18 

16 

14 

12 

11-12 

16 

16 

14 

12 

&

$

!"&

$ !$

!" %&  $ !"

) !"$ !  % "

Summary of Contents for 240-4823

Page 1: ...UR SAFETY Read and understand this manual before use Keep this manual for future reference For questions comments technical assistance or repair parts Please Call Toll Free at 1 866 384 8432 M F 8am 5...

Page 2: ...y materials FOR YOUR SAFETY CAREFULLY READ AND UNDERSTAND ALL INSTRUCTIONS Table of Contents Safety Instructions and Warnings Double Insulation Instructions Extension Cord Unpacking and Checking Carto...

Page 3: ...utdoors or dropped into water return it to an independent service center Do not pull or carry by cord use cord as handle close a door on cord or pull cord around sharp edges or corners Do not run Wet...

Page 4: ...ACUUM TWO SYSTEMS OF INSULATION ARE PROVIDED INSTEAD OF GROUNDING NO GROUNDING MEANS IS PROVIDED ON A DOUBLE INSULATED APPLIANCE NOR SHOULD A MEANS FOR GROUNDING BE ADDED SERVICING A DOUBLE INSULATED...

Page 5: ...Tool H Round Dusting Brush I Extension Wands J Car Nozzle K Cartridge Filter L Filter Retainer M Air Noise Diffuser N Side Tool Caddy O Remote Control Handle P Screws Q Dust Collection Bag R Operator...

Page 6: ...E ASSEMBLY IMPORTANT Do not mount the rack over 5 feet from the floor Do not screw the rack to drywall only Secure the screws to a stud Do not hang from or sit on the mounting rack Do not exceed 40 po...

Page 7: ...stall the collection bag firmly slide cardboard collar opening onto the vacuum port deflector then position the bag so that it is distributed around the inside of the tank fig 14 DO NOT USE THE DUST C...

Page 8: ...he cartridge filter pre installed if not see page 10 for installation instructions 3 Place filter retainer on top of cartridge filter and tighten down by turning the retainer handle clockwise fig 3 4...

Page 9: ...and or nozzle to the free end of the vacuum hose fig 4 6 Ensure the cartridge filter is dry before dry vacuuming 7 Ensure the power switch is turned off and plug in the power supply fig 5 8 Before tur...

Page 10: ...THE CONTAINER Installing Cartridge Filter 1 Verify that the power cord is disconnected from the outlet fig 1 2 Remove power head and place in upside down position 3 Install the cartridge filter over t...

Page 11: ...aline Battery 1 Take a Phillips screwdriver and remove the screws on the remote control fig 1 2 Slide back the remote cover so that the white triangle on the remote cover points to the unlock symbol f...

Page 12: ...ntainer 4 Switch in the wrong position 4 Press the ON I button on the power head Dust comes out from motor cover 1 The cartridge filter is missing or damaged 1 Attach or replace cartridge filter Reduc...

Page 13: ...13...

Page 14: ...parts including but not limited to blades brushes belts bits light bulbs and or batteries 2 shall be void if this tool is used for commercial and or rental purposes and 3 does not cover any losses inj...