25
103090
Figure 28 - Pilot
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B” in the safety information above. If you
don’t smell gas, go to the next step.
5. Slightly depress and turn control knob counterclockwise
C-clockwise
to the PILOT
position. Press in control knob for five (5) seconds (see Figure 27, page 24).
Note:
If running fireplace for first time, there will be air in gas line. You may
need to press in control knob for 30 seconds or longer. This will allow air to
bleed from the gas system.
6. Continue pressing control knob in. Press and release ignitor button. This will light
pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor
button until pilot lights.
Note:
If pilot does not stay lit, contact a qualified service person or gas supplier
for repairs. Until repairs are made, light pilot with match. To light pilot with
match, see Manual Lighting Procedure, page 26.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,
release control knob.
Note:
If pilot goes out, repeat steps 3 through 7.
• If control knob does not pop out when released, contact a qualified service
person or gas supplier for repairs.
Thermocouple
Ignitor Electrode
Pilot Burner
OPERATING
FIREPLACE
Manually-Controlled
Model
Continued
8. Slightly depress and turn control knob counterclockwise
C-clockwise
to the HIGH
position. Both burners should light. Set control knob to either HIGH or LOW.
WARNING ICON
G 001
WARNING
Do not operate heater between pilot and high positions.
WARNING ICON
G 001
CAUTION
Do not try to adjust heating levels by using the manual shutoff valve.
VARIABLE CONTROL OPERATION
The variable control valve can be set to any heat setting and flame height desired, by
simply turning the control knob until that setting is attained. Even the lowest setting
provides realistic flames and glowing embers from two burners. Selecting higher
settings produces greater heat output. This results in increased heating comfort.