1. 

COVER THE SINK DRAINS. 

Place the Home Master

®

 Jr. next 

to sink. Either side OK.   

2.  Unscrew the aerator tip from your sink faucet. If the tip is 

stuck, cover the tip with a rag or towel to protect its finish, 
and use a pair of pliers to loosen. Place the aerator tip in a 
safe place for storage. 

3.  Screw on the diverter valve, or if the thread sizes do not 

match, use the included thread adapter between the diverter 
valve, and the sink faucet.  

4. 

Turn on the COLD water; pull the diverter valve pin until 
water begins to run from the Home Master Jr spout. Some 
water discoloration and air bubbles may be present due to 
loose carbon. Let water run through the Home Master Jr. for 
10-20 minutes to flush out the system completely. 

 

NOTE: Do not filter hot water through your Home Master Jr. 

 

Filter Change Instructions 

Tools Required 

Towel   

 

Unscented Bleach 

 

1.  Turn off water supply to filter.  

2.  Unscrew housing by hand. “Righty-tighty, lefty-loosey” If 

housing is stuck, try harder, or enlist the help of a friend. In 
the worst case you may send the unit to us for service. 
Please call to inquire. 

Page 3 

Home Master

®

  Jr. Series Installation & Service Manual 

3.  Remove used cartridge and discard. Remove O-ring 

from sump and wipe groove and O-ring clean. 
Lubricate O-ring with a coating of clean silicone 
grease. DO NOT use Vaseline or petroleum based 
lubricant. Place O-ring back in place and press O-ring 
down into the groove with two fingers. 

NOTE: This step is important to ensure proper filter 
seal. Make sure the O-ring is seated level in the 
groove. If O-ring appears damaged or crimped it 
should be replaced at this time.  

4.  Rinse out housing and fill about 1/3 full with water. 

Add about 2 to 3 tablespoons of  unscented bleach and 
scrub thoroughly with a CLEAN brush or sponge. Rinse 
thoroughly. Allow to air dry. 

5.  Insert a new cartridge into the sump making sure that 

it slips down over the sump standpipe. If the filter has 
an orientation arrow, make sure it is pointing towards 
the inlet and outlet. Usually this means that the arrow 
will be pointing down when in service. 

6.  Screw the sump onto the cap and tighten hand-tight.  

7.  Turn on the water supply slowly to allow housing to fill 

with water.  

8.  Run water 10-20 minutes until water runs clear and 

free from air bubbles. 

9.  Check for leaks before leaving installation. If unit leaks 

then replace o-ring. 