background image

INFRARED THERMOMETER

TM0819 

Instruction Manual

HORMES LIMITED

[email protected]

G/F UNIT 3, 61 GLENTHORNE ROAD, 

LONDON W6 0LJ UNITED KINGDOM 

+44 203 7695377

Retailer
Email

Address

Telephone

Summary of Contents for TM0819

Page 1: ...INFRARED THERMOMETER TM0819 Instruction Manual HORMES LIMITED cs perfectprime com G F UNIT 3 61 GLENTHORNE ROAD LONDON W6 0LJ UNITED KINGDOM 44 203 7695377 Retailer Email Address Telephone ...

Page 2: ... Introduction 2 Safety 3 Product Description 4 Show 5 Operation Instruction 6 Attention 7 Distance Coefficient Ratio 8 Emissivity and Infrared Temperature Measurement Principle 9 Emissivity values of common materials 10 Specification 2 2 3 3 4 7 8 8 9 10 ...

Page 3: ...f infrared radiation from objects Time saving Only a press on the trigger is needed for measurement User friendly Laser beam allows you to aim at objects more easily Adjustable Maximum and minimum temperatures can be displayed TM0819 is the ideal selection for electrician maintenance personnel technicians and even the emergency personnel 2 Safety Be cautious when laser is working Do not point dire...

Page 4: ... 4 Measuring trigger 5 Battery cover 2 1 3 4 5 4 Show 1 Scanning and measuring procedure 2 Hold and keep the last measuring data 3 Emissivity setting 4 F and C swift 5 Main temperature display 6 Low voltage warning 7 Function transformation zone SCAN HOLD C F ε 0 95 8 8 8 8 LOG 8 8 8 8 8 8 8 8 1 2 6 3 4 5 7 ...

Page 5: ...stay on the screen for 7 sec after the trigger is released and it will power off if there is no other operation Notice Press the MODE button for 2 sec when the instrument is on to swift between F and C 5 1 Temperature Measuring Dual laser distance is within 120cm the temperature measured is 10cm in diameter at this distance 5 2 Dual laser spot 1 Press and release the trigger 2 When hold is display...

Page 6: ...the screen 4 Backlit will be remained stored stage until it change to another model Press up and down button to adjust emissivity when it shows HOLD The emissivity of this instrumentis between 0 1 1 0 Remark backlit will consume the power of battery Turn it off when you need not 5 5 Backlight 1 It can enter max value min value average value max alarm point min alarm point external probe not used 2...

Page 7: ...erature press the up and down menu LAL To set the min alarm temperature press the up and down menu This product can alarm when the temperature is too high or too low It can make a sound to remind the users You can set the alarm temperature through the MODE menu Setting will be saved even when device is turned off F and C can be set by the temperature unit switch menu press the MODE menu for 2 sec ...

Page 8: ...g If the object is transparent such as glass it may not have an accurate result Steam dust smog etc will influence the measuring result This instrument can adjust the environment temperature deviation But if the deviation is huge it may take about 30 minutes to adjust To find the hot spot please point the object from top to bottom and from left to right until found When it shows low power signals ...

Page 9: ... thermometer is an instrument that measures the surface temperature It is through infrared emission reflection and then converted into energy Thermometer converts the electrical signals into temperature reading displayed on the LCD The infrared energy released is in direct proportion with its temperature and emissive power This is called emissivity It is related to the material and gloss of the ob...

Page 10: ... 0 98 Cement 0 96 Lather 0 75 0 80 Sand 0 90 Charcoal powder 0 96 Soil 0 92 0 96 Lacquer 0 80 0 95 Water 0 92 0 96 Lacquer matte 0 97 Ice 0 96 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 85 0 95 Glass 0 90 0 95 Timber 0 90 Ceramics 0 90 0 94 Paper 0 70 0 94 Marble 0 94 Chromium oxides 0 81 Plaster 0 80 0 90 Copper oxides 0 78 Mortar 0 89 0 91 Iron oxides 0 78 0 82 Brick 0 93 0 96 Textiles 0 90 ...

Page 11: ...F 1 0 rdg 1 C 2 F 204 C to 426 C 400 F to 800 F 1 5 rdg 1 C 2 F 426 C to 1050 C 800 F to 1922 F 3 rdg 1 C 2 F Note Accuracy is specified for the following ambient temperature range 23 to 25 C 73 to 77 F Emissivity 0 10 to 1 00 adjustable Field of View D S Approx 12 1 ratio D distance S spot or target Laser pointer Dual Class 2 laser 1mW power Wavelength is 630 to 670nm IR Spectral response 8 to 14...

Page 12: ...0 C to 50 C 32 F to 122 F 10 to 90 RH operating 80 RH storage 10 to 60 C 14 to 140 F 9V battery 7 seconds with LOCK to disable 150g 180 x 107 x 40mm Display Response Time Beyond Read Range Indication Operating Temperature Operating Humidity Storage Temperature Power Supply Automatic Power Off Weight Dimensions ...

Page 13: ...espond Thank you for your understanding For more information about our products and services please fill out the form below or alternatively send us an email cs perfectprime com For B2B or project based application please send an email sales perfectprime com FOR MORE INFORMATION ABOUT PERFECT PRIME PLEASE VISIT OUR ABOUT US PAGE AND FEEL FREE TO BROWSE CONTACT US WHATEVER YOUR QUESTION WE RE HERE ...

Reviews: