background image

HORMES LIMITED

[email protected]

G/F UNIT 3, 61 GLENTHORNE ROAD, 

LONDON W6 0LJ UNITED KINGDOM 

+44 203 7695377

Retailer
Email

Address

Telephone

Summary of Contents for TC0520 E

Page 1: ...Datalogger Thermometer TC0520 Instruction Manual...

Page 2: ...p Options 7 2 Menu Item 7 3 Menu Description 7 3 2 Select thermocouple type 7 3 3 Setting interval time for data storing 7 3 4 Set offset to compensate for probe errors 7 3 5 Set alarm point only for...

Page 3: ...ully before attempting to operate or service the meter Use the meter only as specified in this manual otherwise the protection provided by the meter may be impaired ENVIRONMENT CONDITIONS Altitude up...

Page 4: ...upport K J E T type thermocouple Temperature alarm function Fast response and sampling rate 16 000 data logger records each channel Instant recall function USB PC interface with Windows software inclu...

Page 5: ...382 F T 200 C 400 C 328 F 752 F 0 1 C 600 C 0 1 F 1000 F 1 C 600 C 1 F 1000 F Accuracy is specified for ambient temperatures between 18 C 64 F and 28 C 82 F The specifications do not include thermocou...

Page 6: ...s Weight Standard Accessories 1 time per second UM 4 or AAA 1 5V battery x 4 Approx 100 hours alkaline battery 0 C to 50 C 32 F to 122 F 10 to 90 RH no condensing 20 C to 60 C 4 F to 140 F 10 to 75 RH...

Page 7: ...tor Recording data logger indicator Memory full indicator Memory group indicator Recall Memory group reading indicator Thermocouple type Temperature reading Temperature channel Temperature subtraction...

Page 8: ...Power ON OFF Button Back Light Button MAX MIN AVG Button DATA HOLD Button C F Button 2 3 4 5 6 7 1 REC Button RECALL Saved Reading Button SETUP Button MEM Button Set 100 Memory USB Interface Tilt Stan...

Page 9: ...gain to exit Data Hold mode Note When the unit is in the Data Hold mode and buttons are disabled 6 4 REC Button Press button to start recording data The symbol will display on the screen To stop recor...

Page 10: ...tton to select MEM group The LCD shows hour minute second on the screen for 2 seconds and then shows the readings Press or button to exit RECALL mode 6 7 MAX MIN AVG Button Under this mode the unit si...

Page 11: ...xit MAX MIN AVG mode 6 8 Selecting Temperature Units Press the button to switch between Celsius C and Fahrenheit F 6 9 SETUP Button Press the button to enter setup options Press again to exit setup mo...

Page 12: ...ing the button to adjust parameters or move setting items 3 Press the button to save changes and move to next setting option 1 Fig 1 Set thermocouple type 2 Fig 2 Set interval time for data logging 3...

Page 13: ...e K J E or T Press the or button to select thermocouple type see Fig 8 Fig 8 7 3 2 Setting interval time for data storing 1 Press the or button to set minute or second see Fig 9 2 Press the button to...

Page 14: ...o increase decrease value Note The offset to compensate for probe errors range 5 C or 9 F The user can adjust the readings of thermometer to compensate for the errors against a specific thermocouple F...

Page 15: ...hen measuring thermocouple value over alarm point the symbol will blink or on the LCD The beeper will make beep beep beep sound The Lo alarm set cannot be greater than Hi alarm set seconds Fig 13 7 3...

Page 16: ...h the measurement value Fig 17 Fig 18 1 Press the or button to select year date or time see Fig 19 2 Press the button to increase decrease value Fig 19 Note Check the clock setting after replacing bat...

Page 17: ...ton then LCD will show CLr and SUrE 5 4 1 0 until clean the memory To abort release button before SUrE 0 The LCD will show CLr 0 and start erasing group 00 to 99 records 7 6 Connecting to a computer T...

Page 18: ...blink on the LCD display and the battery needs to be replaced 2 Before replacing the battery power off the meter and disconnect all temperature probes Open the cover of the battery cabinet by a screwd...

Page 19: ...clean lint free antistatic and dry cleaning cloth Do no use cleaning agents that contain carbon or benzenes alcohol or anything similar to clean the product since these substances damage the surface...

Page 20: ...pages manual under TC0520 Recommended screen resolution 1024X768 or above 10 4 Tutorial Quick Start to Use SE520 1 Power on the 4 Channel Thermometer first and connect it to a PC USB port with the ca...

Page 21: ...h window 1 Click the graph window you want to save and the graph window will become active then choose File Save from main menu or click from the tool bar 5 When the connection is successful click Rea...

Page 22: ...format file can be opened by SE520 and Microsoft EXCEL Note If decimal separator is comma in your country this file format will be disabled because CSV file also use comma to be data separator For ex...

Page 23: ...acitve window graph or list Select printer Terminates program By opening the Panel Window the user can control meter via the button in this window Open Real Time Graph display to graph the present da...

Page 24: ...P 23 10 TESTLINK SE 520 SOFTWARE 10 8 DataLogger By opening the DataLogger Window the user can load recorded data of meter to PC in this window Graphing tabular data DataLogger Output To Graph...

Page 25: ...icator to show the loading status If error occurs just click DataLogger icon again After the data was downloaded the left hand side will show how many data sets were loaded and detail information for...

Page 26: ...P 25 10 TESTLINK SE 520 SOFTWARE Graph Tool Bar Display or hide Statistic1 Display or hide Statistic2 Normal cursor...

Page 27: ...raph This is available only when Split option is unchecked And all the mark you make will exist with T1 When selected the mouse cursor will become a I sign when moving to the graph click on the graph...

Page 28: ...o the Zoom You can Zoom this graph by using mouse To Zoom 1 Press the left mouse button and drag the cursor to select the new extents 2 Release the mouse button You can choose channel number showing i...

Page 29: ...h button then it will remove the SE520 folder and files from your computer 2 How to zoom the graph Answer Press the left mouse button and drag the cursor to select the new extents then release the mou...

Page 30: ...r products and services please send us an email cs perfectprime com For B2B or project based application please send an email sales perfectprime com FOR MORE INFORMATION ABOUT PERFECTPRIME PLEASE VISI...

Page 31: ...HORMES LIMITED cs perfectprime com G F UNIT 3 61 GLENTHORNE ROAD LONDON W6 0LJ UNITED KINGDOM 44 203 7695377 Retailer Email Address Telephone...

Reviews: