11. Measure Objects
The product is provided with four types of object measurement modes:
①
Coarse object (0.95);
②
Semi-matte object (0.80);
③
Semi-shiny object (0.60);
③
Shiny object (0.30);
According to the characteristics of the measured objects, users may select
corresponding measurement mode and enter “advanced” option to adjust the value of
emissivity (please refer to the table of “emissivity of common materials”).
The operating step is as the following:
After the item is selected, press “SELECT”/ “ENTER” to enter the setting state. Press
“ ”/“ ” to adjust the value. After completion, press “SELECT”/ “ENTER” to exit
from such setting.
Select the “measure objects”; press “
” key of
navigation key to enter the submenu.