7.PRECAUTIONS

P.9

1. 

When the meter is working, keep it away from vibration sources and 

strong electromagnetic fields, and environmental locations with 
drastic temperature changes, so as not to be interfered and cause 
inaccurate measurement data. 

2. 

When measuring corrosive and toxic gases or liquids, please take 

precautionary measures to avoid danger or damage to the 
instrument

3. 

Please replace the battery in time when the meter shows a low 

battery level and remove the battery when it is not used for a long 
time to avoid battery leakage and damage the meter.

4. 

When measuring the pressure input maximum value, please do not 

exceed the scope of the instrument measurement.

5. 

When measuring the pressure of a single channel, please do not 

block the other channel, and do not apply wind or strong airflow. At 
this time, the meter displays the difference between the current 
measurement port and the atmospheric pressure. 

6. 

When the screen shows over range during measurement, please 

disconnect the vent hole. The displayed data will automatically 
return to normal. (Pa units can only be displayed up to 9999, 
adjustable to kpa units.

7. 

Before connecting to the trachea, please press and hold the hold 

button to clear the zero drift to ensure accurate measurement data

Summary of Contents for AR168

Page 1: ...Digital Pressure Gauge AR168 Instruction Manual...

Page 2: ...2 2 3 4 5 6 7 8 9 CONTENTS P 1 1 PRODUCT INTRODUCTION 2 BASIC FUNCTIONS 3 TECHNICAL PERFORMANCE 4 RANGE OF PRESSURE MEASUREMENT 5 SYMBOL DEFINITION BUTTON LOCATION 6 KEY OPERATION 7 PRECAUTIONS...

Page 3: ...the pressure difference between two detection ports The product is widely used in natural gas pipelines air conditioning refrigeration and ventilation systems mechanical hydraulics plastic molding bi...

Page 4: ...ic shutdown conditions Positive pressure range display Over negative pressure range display Working Temperature Working Power Physical dimension Weight 2 999 Psi Psi kg cm2 ozin2 bar mbar Pa kPa inHg...

Page 5: ...MEASUREMENT Unit kPa psi kgcm ozin bar mbar inHg mmHg inH2O ftH2O cmH2O Pa Range 20 68 2 999 0 210 47 99 0 206 206 8 6 106 151 1 83 02 6 918 210 8 9999 Resolution 0 001 0 001 0 001 0 01 0 001 0 1 0 0...

Page 6: ...5 SYMBOL DEFINITION BUTTON LOCATION P 5 1 2 3 6 7 4 5 Temperature Display Low Power Symbol Hold Function Max Min Reading 2 3 4 1 Differential Pressure Mode Reading display Pressure Units 6 7 5...

Page 7: ...TION BUTTON LOCATION P 6 Power on off Button C F Button HOLD Button UNITS Button DIF Button MAX Button 2 3 4 5 6 1 LCD Display Tube Connector Tube Connector Label position Hanging Hole Battery Cover 7...

Page 8: ...Press and hold for more than 2 seconds to switch the C F unit 3 HOLD Button a Press to lock and hold the current data b Press and hold for more than 2 seconds to clear the drift zero The data before...

Page 9: ...RATION P 8 6 MAX Button a Short press to view stored data b Press and hold for 2 seconds to enter the maximum and minimum mode c Press and hold for more than 2 seconds to return to the normal measurem...

Page 10: ...ery leakage and damage the meter 4 When measuring the pressure input maximum value please do not exceed the scope of the instrument measurement 5 When measuring the pressure of a single channel please...

Page 11: ...r products and services please send us an email cs perfectprime com For B2B or project based application please send an email sales perfectprime com FOR MORE INFORMATION ABOUT PERFECTPRIME PLEASE VISI...

Page 12: ...HORMES LIMITED cs perfectprime com G F UNIT 3 61 GLENTHORNE ROAD LONDON W6 0LJ UNITED KINGDOM 44 203 7695377 Retailer Email Address Telephone...

Reviews: