background image

6

 STEP 1: 

PREPARING THE EXHAUST HOSE  

ASSEMBLY 

Fig. 9

Press the exhaust hose into the window slider adapter and 

unit adapter; it will snap automatically to the adapters.

 STEP 2: 

INSTALL THE EXHAUST HOSE ASSEMBLY 

TO THE UNIT 

Fig. 10

Slide the Exhaust hose into the air outlet opening of the 

unit along the arrow direction, from left to right.

 STEP 3: 

PREPARING THE ADJUSTABLE WINDOW 

SLIDER 

Fig. 11

a.  Depending on the size of your window, adjust the size of 

the window slider.

b. If the length of the window requires two window sliders, 

use the bolt (included) to fasten the window sliders once 

they are adjusted to the proper length.

NOTE: 

To ensure proper function,

 DO NOT

 overextend or 

bend the hose. Make sure that there are no obstacles 

around the air outlet of the exhaust hose (20 inch 

clearance) in order to ensure the exhaust system works 

properly. (Fig. 12.)

Once the Exhaust Hose assembly and Adjustable Window 

Slider are prepared, choose from one of the following two 

installation methods:
•  Hung Window Installation (page 7)
•  Sliding Window Installation (page 8)

FIG. 9

FIG. 10

FIG. 11

FIG. 12

Unit Adapter

Hook

Adapter

Bolt (if needed)

Window Slider A

Window Slider B

Lower 

Groove

Make sure the 

adapter is inserted 

into the lower groove 

of the air outlet.

Notch

Window Slider 

Adapter

Exhaust Hose

Exhaust Hose Assembly

 

RECOMMENDED INSTALLATION

19.7 inches

50 cm

NOTE: 

All the illustrations in this manual are 

for explanation purposes only. Your unit 

may be slightly different. The actual shape 

of the unit prevails.
The unit can be controlled by it’s control 

panel or with the remote control. This 

manual does not include remote control 

operations. See the Remote Control User 

Manual included with the unit for details.

Summary of Contents for PORT10000

Page 1: ...LE AIR CONDITIONER FOR MODELS PORT8000 PORT10000 PORT12000 PORT14000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER M...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...e listed in the accessories chart of this Instruction Manual ENERGY SAVING TIPS Use the unit in the recommended room size Locate the unit where furniture cannot obstruct the air flow Keep blinds curta...

Page 4: ...replacement work should be performed by authorized personnel only Installation and repair work must be performed in accordance with the national wiring standards by authorized personnel only DO NOT op...

Page 5: ...Do not place your air conditioner where it can fall or be pulled into water or any other liquid If the unit does ever fall into water unplug it immediately DO NOT install the unit in a location that m...

Page 6: ...c Security Bracket and 2 Screws 1 set Drain Hose 1 pc Power Cord Buckle 1 pc ON OFF TEMP S HO R T C U T T IME R O N T IME R O F F MO DE FAN S L E E P S W ING L E D Remote Control and Batteries 1 set N...

Page 7: ...Cord Buckle used only when storing the unit 9 Power Cord Outlet 10 Bottom Tray Drain Outlet 11 Lower Air Filters A B behind the grille 12 Lower Air Intake 13 Upper Drain Outlet AIR FLOW DIRECTION ADJU...

Page 8: ...ry for you to improvise or modify some aspects of the installation procedures for certain types of windows Please refer to Fig 6 and Fig 7 for minimum and maximum window openings Window slider kit len...

Page 9: ...of the exhaust hose 20 inch clearance in order to ensure the exhaust system works properly Fig 12 Once the Exhaust Hose assembly and Adjustable Window Slider are prepared choose from one of the follo...

Page 10: ...he glass and the window frame to prevent air and insects from getting into the room STEP 4 Fig 16 If desired install the security bracket with 2 screws as shown STEP 5 Fig 17 Insert the window slider...

Page 11: ...the glass and the window frame to prevent air and insects from getting into the room STEP 4 Fig 21 If desired install the security bracket with 2 screws as shown STEP 5 Fig 22 Insert the window slider...

Page 12: ...a floor drain making sure that there are no kinks that will stop the water flow Place the end of the hose into a drain and make sure the end of the hose is directed downward to let the water flow smo...

Page 13: ...ean cloth 3 UNIT IDLE FOR A LONG TIME Remove the rubber plug on the back of the unit and attach a hose to drain outlet Place the open end of the hose directly over the drain area in your basement floo...

Page 14: ...ntrol the fan speed Press to select one of three fan speeds LOW MID HIGH or AUTO The fan speed indicator light illuminates next to the different fan settings 5 TIMER button Used to initiate the AUTO O...

Page 15: ...the Follow Me feature has ended The display on the remote control indicates the temperature at the remote ONLY TIMER operation IF SETTING THE TIMER WHEN THE UNIT IS ON First press the TIMER button the...

Page 16: ...s call Consumer Services E3 Condenser Temperature Sensor Error Unplug the unit and plug it back in If error repeats call Consumer Services E4 Display Panel Communication Error Unplug the unit and plug...

Page 17: ...N only mode Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN only mode Thermostat is set too cold for night time cooling To defrost the coil set to FAN onl...

Page 18: ......

Page 19: ......

Page 20: ...by Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_PO...

Reviews: