12. To remove front: 

 (Fig. 10)

Remove the two front retaining screws from 

the front frame. 

Gently pull the front out and lift up to release

it from the case.

Release the coupler plugs.

NOTE: 

DO NOT push or pull air directional 

louvers.

13. Place the air conditioner in the window
opening. 

(Fig. 11)

The air conditioner should sit on the platform 

assembly so that the window panel frame, and

the cabinet side channels are against the top and 

side window jambs. Side channels should overlap

side window jambs equally.

14. Drill two 9/64 inch diameter pilot holes.

Drill the two pilot holes in the top window jamb in

line with the partially plugged holes in the panel 

frame. Secure the panel frame to the window jamb

with two 3/4 inch self-threading screws. If additonal 

holding is necessary, two screws may be used on 

the sides of the panel frame as well.

15. Drill screw-clearance holes. 

Drill two screw-clearance holes in the cabinet side 

channels (near bottom) and two 9/64 inch diameter 

pilot holes in the side window jambs. Secure the 

cabinet side channels to the window jambs with

two 3/4 inch self-threading screws. When doing 

this, be careful not to twist the side channel seals

with the screws.

NOTE: 

Inserting screws will prevent the air conditioner

from being pushed into the room.

16. To replace the front.

First, reconnect the coupler plugs, make the exhaust 

control positioned through the front in the proper location.

Then replace the retaining screws that hold the panel in

place. Do not  push or pull the front panel louvers. 

Fig. 10

Fig. 11

INSTALLATION INSTRUCTIONS (CONTINUED)

Summary of Contents for PASC10000

Page 1: ... your casement slider air conditioner please read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort FOR MODELS PASC10000 PASC12000 CASEMENT SLIDER AIR CONDITIONER USER MANUAL ...

Page 2: ...Disabled persons may require assistance with set up If the power cord is to be replaced replacement work should be performed by authorized personnel only Installation and repair work must be performed in accordance with the national wiring standards by authorized personnel only Do not operate your air conditioner in a wet room such as a bathroom or laundry room Units with a heating function should...

Page 3: ...use explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may cause fire and electric shock Doing so may cause fire and electric shock Doing so may cause electric shock or fire If the power cord is damaged it must be replaced by the manufacturer or an authorized se...

Page 4: ...f time turn OFF main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified serviced technician Obstacles may cause appliance failure or accident Cleaners or detergents may change the color or scratch the surface of the unit Do not place obstacles around air inlets or inside ...

Page 5: ...orized repairman Operation of Current Device 1 Plug in the air conditioner 2 The power supply cord will have TWO buttons on the plug head Press the TEST button The RESET button will click as it pops out 3 Press the RESET button again you will notice a click as the button engages 4 The power supply cord is now supplying electricity to the unit On some products this is also indicated by a light on t...

Page 6: ...insulating materials DO NOT use for grounding Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded DO NOT modify power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician DO NOT have a fuse in the neutral or grounding circuit A fuse in the neutral or grounding circuit could result in an electric...

Page 7: ...OL OPERATING INSTRUCTIONS 6 AIR CONDITIONER FEATURES NOTES If the unit breaks off unexpectedly due to power being cut it will restart with the previous function setting automatically when the power resumes In Fan only mode unit will display Lo or Hi Error Codes AS Room temperature sensor error Unplug the unit and plug it back in If error repeats call customer service Evaporator temperature sensor ...

Page 8: ... circulation or to exhaust stale air Remember to open the vent during this function but keep it closed during cooling for maximum cooling efficiency You can choose any fan speed you prefer During this function the display will show the actual room temperature not the set temperature as in the cooling mode To operate on Dry mode In this mode the air conditioner will reduce air humidity If the space...

Page 9: ...light beside the word On will illuminate indicating the Auto Start program is on Press or hold the left Temp Timer arrow or right Temp Timer to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The selected time will register for 5 seconds and the system will automatically revert back to di...

Page 10: ... exhaust air to the outside Open The closed position is used when maximum cooling is desired It may also be used for air re circulation without cooling when the air conditioner is set in any FAN position The Open position removes stale air from the room and exhausts it to the outside Fresh air is drawn in through normal passages in the home FOLLOW ME FEATURE To activate the Follow Me feature point...

Page 11: ...y bracket 1 9 11 Screw 2 1 2 2 or Screw 1 3 4 2 or Screw 1 2 12 Screw 3 4 6 13 Screw 3 4 self threading 7 14 Window locking bracket 1 15 Plastic window panel 1 16 Side channel 2 17 Screw 3 8 6 18 Panel frame seal assembly 1 Tools Required Not included Flat head screwdriver Phillips head screwdriver Carpenter s level Tape measure Fine tooth saw Electric or hand drill NOTE These instructions describ...

Page 12: ... Also choose a window that is within 6 feet of an electrical outlet See Meeting Electrical Requirements Receptable Wiring Needs on Page 5 Do not use an extension cord 16 1 4 inches maximum width casement windows 15 1 2 inches minimum width 20 5 16 inches minimum height 39 7 16 inches maximum height 3 4 or 1 3 4 or 1 or Identify Screws By Length 25mm 1 44mm 1 3 4 63mm 2 1 2 3 8 10mm 3 4 19mm NOTE U...

Page 13: ...orm assembly Fig 3 and Fig 4 Center the platform assembly on the line with inside platform tab pressed against inside edge of window track Using the holes in the platform as a guide mark and drill two 9 64 diameter holes Drill holes in either track or stool 4 Peel off protective backing from track seal Fig 5 Next apply seal to room side of window track Center of seal strip should coincide with the...

Page 14: ...lamp the plastic window panel between a board and a work table and cut along cutting line with a fine tooth saw Remove any burrs with a file 11 Fasten side channels Fig 9 Fasten the side channels to the sides of the unit using 3 screws Item 17 page 10 per channel Start with first screw at top of channel Make sure hook ends of channels face toward back of unit 12 Slide plastic window panel into pan...

Page 15: ...ilot holes for the screws 17 Hook the safety bracket Fig 14 The safety bracket should be hooked over the base of the unit and fastened to the front of the platform assembly Use a 3 4 inch self threading screw NOTE The bracket prevents movement of the air conditioner either in or out after completing the installation 18 Stuff the foam seal strip sash seal Stuff the foam seal strip between the verti...

Page 16: ... support brace Try the assembly in the window to determine if the platform will rest properly and allow the proper slope 5 16 inch lower on outside NOTE If you are planning to use a siding protection board See Step 6 on the outside of your house hold the board in place when testing the assembly in the window 2 Drill a 9 64 inch diameter pilot hole Drill the hole in the window jamb an equal distanc...

Page 17: ... window panel between a board and a work table and cut along the cutting line with a fine tooth saw Remove any burrs with a file 9 Fasten the side channels to the side of the unit Using three screws Item 17 Pg 10 per channel fasten the side channels to the side of the unit Make sure hook ends of channels face toward the back of unit 10 Slide the plastic window panel into panel frame Fig 8 Slide th...

Page 18: ...me Secure the panel frame to the window jamb with two 3 4 inch self threading screws If additonal holding is necessary two screws may be used on the sides of the panel frame as well 15 Drill screw clearance holes Drill two screw clearance holes in the cabinet side channels near bottom and two 9 64 inch diameter pilot holes in the side window jambs Secure the cabinet side channels to the window jam...

Page 19: ...he air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping the controls Excess water in or around the control...

Page 20: ...are and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher setting UNIT WILL NOT TURN ON Reset circuit breaker Make sure there are not too many items ie lamps TV s etc working off the same breaker Check plug connection If plug is operating on an on off switch be sure that the s...

Page 21: ...e for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in PRC 877 365 6274 www perfectaire us ...

Reviews: