Perfect Aire 4PADP95 User Manual Download Page 11

8

OPTION 3: PUMP DRAINING

Water can be automatically emptied into a floor drain or a suitable  

drainage facility by attaching the pump drain out with a pump drain hose  

(

φ 

1/4", supplied).

•  Remove the continuous drain hose from the unit and install the plastic cover 

to the continuous drain hose outlet of the unit by rotating it clockwise. (See 

Fig. 13.)

•  Reset the pump drain hose into the pump drain hose outlet for depth of at 

least 15mm (See Fig. 13), then lead the water hose to the floor drain or a 

suitable drainage facility.

•  Press the pump pad of the unit to activate the pump operation. When the 

bucket is full, the pump starts to work. NOTE: The pump may cause loud 

noise for the first 3 – 5 minutes after it begins operating.

•  Make sure the hose is secure so there are no leaks.

•  Direct the hose toward the drain, making sure that there are no kinks that will 

stop the water from flowing.

•  Place the end of the hose into the drain and make sure the end of the hose 

is level or down to let the water flow smoothly. Never let it up.

•  Select the desired humidity setting at fan speed on the unit for pump 

draining to start.

NOTES: 

The pump operation on light blinks at 1Hz when the pump is in operational 

failure. Please turn off the unit and unplug the power cord. Check the  

following items:

•  Cleaning the filter of the pump: Remove the bucket from the unit, take down 

the pump and clean the filter of the pump. (See Fig. 14.)

•  Check that the pump drain hose does not link or block.

•  Empty the water from the bucket.

•  Reinstall the pump hose if it drops and reinstall the bucket properly. Turn on the unit. If the error repeats, call 

Consumer Services at 844-472-2473. 

NOTE:

 Do not use this operation when the outdoor temperature is equal to or less than 32°F (0°C). Otherwise, water 

will become ice that will cause the water hose to block up and unit to fail. Make sure to empty the bucket once a week 

when using the pump draining feature. When the pump draining feature is not being used, remove the pump drain 

hose from the outlet.

•  Press the pump drain hose outlet in and take the pump drain hose out from it. (See Fig. 15.) Make sure not to let the 

water in the pump hose drip onto the floor.

OPTION 3: PUMP DRAINING

FIG. 13

FIG. 14

FIG. 15

Reinstall the 

Plastic Cover

Pump Drain Hose

1. Press the  

  pump drain  

  hose outlet in.

2. Take the pump 

  drain hose out.

Pump Filter

Pump Drain 

Hose Outlet

Summary of Contents for 4PADP95

Page 1: ...IER USER MANUAL Be sure to read the QUICK START TIPS on the next page FOR MODEL 4PADP95 Before using your dehumidifier please read this manual carefully and keep it for future reference along with you...

Page 2: ...g you to properly set up and begin to use your dehumidifier 1 The dehumidifier should be kept upright If for any reason it has not been stored upright while in your possession put the unit in an uprig...

Page 3: ...purchased may be slightly different NOTE The design and specifications of the dehumidifier are subject to change without prior notice for product improvement Contact Consumer Services at 844 472 2473...

Page 4: ...Failing to do so may cause fire and electric shock You should never try to take apart or repair the unit by yourself This may cause failure of machine or electric shock Before cleaning turn off the p...

Page 5: ...two weeks Operation without filters may cause failure If water enters the unit turn unit off disconnect power and contact a qualified service technician This may cause failure of dehumidifier and ther...

Page 6: ...lled into the unit and the continuous drain hose is removed from the unit before the pump operation is activated When the bucket is full the pump will initiate Refer to the next pages for removing the...

Page 7: ...light will be lit up only when the accumulated operation time achieves 250 hours or more The CLEAN FILTER Indicator light flashes once every second After cleaning the air filter press and hold the FI...

Page 8: ...E FLOAT DOES IT NEED THE FOAM PIECE INSIDE OF IT Inside the bucket on the left side is an arm mechanism that wobbles This piece is called the float DO NOT remove the foam piece that is found in the pl...

Page 9: ...USING THE UNIT A dehumidifier operating in one room will have little or no effect in drying an adjacent enclosed area such as a closet or other room unless there is adequate circulation of air in and...

Page 10: ...er can be automatically emptied into a floor drain by attaching a water hose garden hose or dehumidifier drain hose to the dehumidifier Garden hose must be 5 16 with a female threaded end with ID M 1...

Page 11: ...unit for pump draining to start NOTES The pump operation on light blinks at 1Hz when the pump is in operational failure Please turn off the unit and unplug the power cord Check the following items Cle...

Page 12: ...with clean water and add a small amount of mild detergent Swish it around in the bucket empty and rinse NOTE DO NOT use a dishwasher to clean the bucket After cleaning the bucket it must be securely i...

Page 13: ...WATER Be sure unit is not too large or too small for the area of the room When first installed run unit on Continuous Mode for 24 hours Allow enough time for unit to remove moisture Set humidity low e...

Page 14: ...is obstructing hose connection and there are no kinks or tears in any of the hosing Ensure unit is level and not tilted forward and that bucket is pushed in all the way Though the unit may appear lev...

Page 15: ...12...

Page 16: ...y Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_4PA...

Reviews: