2

CAUTIONS

When removing air filter, 

DO NOT

 touch metal parts of 

the unit.

Doing so may cause an injury.

DO NOT

 clean with water.

Water may enter the unit and degrade the insulation 

causing an electric shock.

Ensure proper ventilation especially in rooms with a 

stove or other appliances.

Failure to do so may result in an oxygen shortage.

Unit and circuit breaker/fuse must be switched OFF 

when cleaning.

Cleaning unit when power is ON may cause fire and 

electric shock and may cause an injury.

DO NOT 

put a pet or house plant where it will be ex-

posed to direct air flow.

This could injure the pet or plant.

Use 

ONLY

 as intended.

This unit is 

NOT

 intended to preserve precision devic-

es, food, pets, plants, and art objects. It may cause 

deterioration of quality, etc.

Stop operation and close the window in severe 

storms or hurricanes.

Operation with windows open may cause moisture to 

enter the room.

Hold the plug by the head of the power plug when 

taking it out.

Failure to do so may cause electric shock  

and damage.

If unit will not be used for a long period of time,  

unplug or turn 

OFF

 main power switch.

Leaving power on may cause unit failure or fire.

Do not place obstacles around air-inlets or inside of 

air-outlet.

Obstacles may cause appliance failure or accident.

Periodically check installation bracket for damage.

Prolonged exposure to outdoor elements may cause 

damage to installation bracket, causing unit to fall.

Always insert filter(s) securely. Clean filter(s) 

AT LEAST

 

once every two weeks.

Operation without securely installed filters may  

cause failure. A dirty filter can cause the unit to not  

run efficiently.

Use only a soft cloth to clean the unit.

Cleaners or detergents may change the color or 

scratch the surface of the unit.

Use caution when unpacking and installing.

Sharp edges could cause injury.

NEVER

 drink water drained from air conditioner.

Water from unit contains contaminants and could 

cause illness.

DO NOT

 place heavy objects on the power cord and 

always ensure that the cord is not compressed.

There is danger of fire or electric shock.

If water enters the unit’s electrical components, turn 

the unit off at the power outlet and switch off the cir-

cuit breaker. Isolate supply by taking the power-plug 

out and contact a qualified serviced technician.

There is danger of electric shock.

Summary of Contents for 3PNC10000

Page 1: ...OW AIR CONDITIONER FOR MODEL 3PNC6000 3PNC8000 3PNC10000 3PNC12000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MAN...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...staller for installation of this unit The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the air...

Page 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Page 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire Do not place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Page 6: ...sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this un...

Page 7: ...pening See Table 1 on next page CAUTION Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of the air conditioner Aluminum...

Page 8: ...r of the packaging material as shown in Fig A TOP RAIL HARDWARE 3 8 Screws 4 pcs Top Rail 1 pc Insulation Panels 2 pcs C Align the hole in the top rail with those in the top of the unit as shown in Fi...

Page 9: ...side Refer to Figure 5 H above to determine proper slope If after proper installation condensation does not drain from the overflow drain hole during normal use adjust slope B Extend the accordion pan...

Page 10: ...in water or condensation must be allowed to drain out FIG 11 Sash Storm window frame or other obstruction 1 min 38 mm Board thickness as required for proper pitch to rear along entire sill Fasten with...

Page 11: ...ting the unit This unit can be controlled by the unit control or with the remote control FOLLOW ME Indicator Energy Saver Mode Sets Mode Sleep Mode Turns Unit On or Off Set Fan Speed Adjusts Temp or T...

Page 12: ...ill be illuminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver function under COOL DRY and AUTO only AUTO COOLING and AUTO FAN modes TO OPERATE AUTO F...

Page 13: ...ded Pivot horizontal louvers until the desired up down direction is obtained Move the levers from side to side until the desired Left Right direction is obtained ADDITIONAL THINGS YOU SHOULD KNOW The...

Page 14: ...ilter Never attempt to operate the unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil fr...

Page 15: ...he coil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the roo...

Page 16: ...Belt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_3PNC6...

Reviews: