background image

Perfect Aire, LLC
5151 Belt Line Rd.
Suite 878
Dallas, TX 75254

Distributed by:

844-4PA-AIRE  |  844-472-2473

www.perfectaire.us

WINDOW

AIR CONDITIONER

FOR MODEL: 

3PASC10000

Before using your air conditioner, please 
read this manual carefully and keep it for 
future reference, along with your receipt.

Specification and performance data is subject to change without notice.

Printed in China

PA/User_3PASC10000/10162017

USER MANUAL

Summary of Contents for 3PASC10000

Page 1: ...WINDOW AIR CONDITIONER FOR MODEL 3PASC10000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...nce of this unit Contact an installer for installation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be superv...

Page 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Page 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire DO NOT place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Page 6: ...sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this un...

Page 7: ...l CASEMENT window Modification may be necessary when installing in windows made differently than those shown in these instructions INSTALLATION TIPS For wood frame casement windows It may be necessary...

Page 8: ...room s you wish to cool Remember it is difficult to move air around corners Also choose a window that is within 6 feet of an electrical outlet See Electrical Information on Page 3 DO NOT USE AN EXTEN...

Page 9: ...r of seal strip should coincide with the line marked in Step 2 The two screw holes drilled in Step 3 should be directly above seal strip in the inner track Fig 5 STEP 5 SECURELY ATTACH A SIDING PROTEC...

Page 10: ...tooth saw Remove any burrs with a file STEP 11 FASTEN SIDE CHANNELS Fasten the side channels to the sides of the unit using 3 screws Item 17 page 4 per channel Start with first screw at top of channe...

Page 11: ...screws Fig 13 STEP 17 HOOK THE SAFETY BRACKET The safety bracket should be hooked over the base of the unit and fastened to the front of the platform assembly Use a self threading screw Fig 14 NOTE Th...

Page 12: ...rm will rest properly and allow the proper slope 5 16 inch lower on outside Fig 1 NOTE If you are planning to use a siding protection board See Step 6 on the outside of your house hold the board in pl...

Page 13: ...e plastic window panel between a board and a work table and cut along the cutting line with a fine tooth saw Remove any burrs with a file STEP 9 FASTEN THE SIDE CHANNELS TO THE SIDE OF THE UNIT Using...

Page 14: ...ndow jamb with two inch self threading screws If additional holding is necessary two screws may be used on the sides of the panel frame as well STEP 15 DRILL SCREW CLEARANCE HOLES Drill two screw clea...

Page 15: ...unit This unit can be controlled by the unit control or with the remote control FOLLOW ME Indicator Energy Saver Mode Sets Mode Sleep Mode Turns Unit On or Off Sets Fan Speed Adjusts Temp or Time Exha...

Page 16: ...t will be illuminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver function under COOL DRY and AUTO only AUTO COOLING and AUTO FAN modes TO OPERATE AUT...

Page 17: ...til the desired Left Right direction is obtained ADDITIONAL THINGS YOU SHOULD KNOW The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly After unit is...

Page 18: ...e unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened...

Page 19: ...coil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the room...

Page 20: ...151 Belt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_3...

Reviews: