background image

-8-

Operating The Unit

Positioning the unit

A dehumidifier operating in one room will have little or no effect in drying an adjacent enclosed area, such as a closet, or other 

room unless there is adequate circulation of air in and out of the area.

•  Do not use outdoors.
•  This dehumidifier is intended for indoor residential 

applications only. This dehumidifier should not be 

used for commercial or industrial applications.

•  Place the dehumidifier on a smooth, level floor, strong 

enough to support the unit with a full bucket of water.

•  Allow at least 8 in. (20 cm) of air space on all sides of 

the unit for good air circulation.

•  Place the unit in an area where the temperature will 

not fall below 41°F (5°C). The coils can become 

covered with frost at temperatures below 41°F (5°C), 

which may reduce performance.

•  Place the unit away from the clothes dryer, heater  

or radiator.

•  Use the dehumidifier to prevent moisture damage 

anywhere books or valuables are stored.

•  Use the dehumidifier in a basement to help prevent 

moisture damage.

•  The dehumidifier must be operated in an enclosed 

area to be most effective.

•  Close all doors, windows and other outside openings 

to the space that you wish to dehumidify.

When using the unit

•  When first using the dehumidifier, operate the unit in "Continuous" mode for 24 hours. 

 

NOTE: After the first 24 hours, should you wish to set a desired humidity, you will need to take the unit off of 

“Continuous.” You will not be able to select a desired humidity while the unit is set on “Continuous” mode.

•  This unit is designed to operate with a working environment between 41°F/5°C and 95°F/35°C.
•  If the unit has been switched off and needs to be switched on again quickly, allow approximately 3 minutes for the 

correct operation to resume.

•  Do not connect the dehumidifier to a multiple socket outlet, that is being used for other electrical appliances.
•  Select a suitable location, making sure you have easy access to an electrical outlet.
•  Plug the unit into an electrical outlet with a grounding connection.
•  Make sure the water bucket is correctly fitted or the unit will not operate properly.
•  NOTE:

 

Do not attempt to move the dehumidifier when there is water in the bucket. The unit may tip over and spill water 

or damage unit.

 

Casters (At four points on the bottom of unit)

•  Casters can move freely.
•  Never force casters to move over carpet or move 

the unit with water in the bucket. (The unit may tip 

over and spill water.)

Fig. 4

8" or more

16" or more

Air intake 

grille

Air outlet 

grille

8" or  

more

8" or  

more

8" or  

more

Summary of Contents for 3PAD30

Page 1: ...using your dehumidifier please read this manual carefully and keep it for future reference along with your receipt FOR MODELS 3PAD30 3PAD50 3PAD70 DEHUMIDIFIER USER MANUAL Be sure to read the Quick S...

Page 2: ......

Page 3: ...set a desired humidity you will need to take the unit off of Continuous You will not be able to select a desired humidity while the unit is set on Continuous mode NOTE You do not need to be in Continu...

Page 4: ...e dehumidifier 10 Troubleshooting Tips Troubleshooting tips 11 12 CAUTION Contact an authorized service technician for repair or maintenance of this unit Contact an installer for installation of this...

Page 5: ...unit near a heat source Before cleaning turn off the power and unplug the unit Do not take the water bucket out during operation You should never try to take apart or repair the unit by yourself Disc...

Page 6: ...ailure of appliance and there is danger of electric shock If unit falls over it may spill water and damage belongings or cause electrical shock or fire This will cause unit deterioration due to chemic...

Page 7: ...es the unit will make a single beep sound to indicate that it is changing modes Mode Toggle between the following features Normal Utilize this mode if you would like the unit to cycle on and off based...

Page 8: ...omatically start after 3 minutes Check Filter Feature The system starts to log the time once the fan motor operates The check filter light will be lit up only when the accumulated operation time achie...

Page 9: ...s are the same WHAT IS THE FLOAT DOES IT NEED THE FOAM PIECE INSIDE OF IT Inside the bucket on the left side is an arm mechanism that wobbles This piece is called the float DO NOT remove the foam piec...

Page 10: ...ce that you wish to dehumidify When using the unit When first using the dehumidifier operate the unit in Continuous mode for 24 hours NOTE After the first 24 hours should you wish to set a desired hum...

Page 11: ...the water hose to the floor drain or a suitable drainage facility A hose length of no more than 6 ft is recommended as the hose must allow the water to continuously travel downward into the drain Make...

Page 12: ...f mild detergent Swish it around in the bucket empty and rinse NOTE Do not use a dishwasher to clean the bucket After cleaning the bucket it must be securely in place for the dehumidifier to operate 3...

Page 13: ...time for unit to remove moisture Set humidity low enough to ensure moisture removal Setting the unit below 45 is not recommended Setting may be the same as actual humidity in room thus no moisture to...

Page 14: ...SE WHEN OPERATING Make sure the air filter is clean and not clogged Make sure the unit is upright not tilted and on a flat level surface If you are using the pump operation the unit may be noisy for t...

Page 15: ......

Page 16: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in China 877 365 6274 www pe...