73
3) Disconnect the
connector for fan motor
from the electronic control
board.
4) Remove the four
fixing screws of the
fan motor. Then remove
the fan motor.
3
Electrical
parts
How to remove the
electrical parts.
1) After finish work of
item 1 and item 2, remove
the connectors for the
compressor.
2) Pull out the two blue
wires connected with the
four way valve.
○
1
○
3
○
4
○
2