background image

Page 17

AUTO  operation

   When you set the air conditioner in AUTO mode, 

   it will automatically select cooling, heating (cooling/

   heating  models only), or fan only operation 

   depending on what temperature you have selected 

   and the room temperature.

   The air conditioner will control room temperature 

   automatically round the temperature point you set.

   

   If the AUTO mode is uncomfortable, you can 

   select desired conditions manually.

SLEEP  operation

   When you push SLEEP button on remote control 

   during cooling, heating or AUTO operation, the air  

   conditioner will automatically increase (cooling) 

   or decrease (heating) 2°F (1°C) per hour.

   The set temperature will be steady 2 hours later.  

   And the air conditioner will be timer off in 7 hours. 

   The fan speed will be automatically controlled. 

   This feature can maintain the most comfortable 

    temperature and saves more energy. 

   

DRYING operation

   The fan speed is automatically controlled under 

   dry operation.

   During the dry operation, if the room temperature 

   is lower than 50ºF (10ºC) the compressor stops 

   operation and restarts until the room temperature 

   is above 54ºF (12ºC). 

How the air conditioner works

1 hour

1 hour

Set 

Temperature

Cooling

o

1 (2 F)

o

1 (2 F)

Heating

SLEEP  operation

o

1 (2 F)

o

1 (2 F)

1 hour

1 hour

Set 

Temperature

SLEEP  operation

7 hours timer off

7 hours timer off

To achieve optimal performance, please note the following:

Adjust the air flow direction correctly so that it is not directed at occupants.

Adjust the temperature to achieve the highest comfort level. Do not adjust the unit  to excessive 

temperature levels.

Close doors and windows on COOL  or HEAT modes, performance will be reduced.

Use TIMER ON button on the remote control to select a specific time you want to start your air conditioner.

 Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner will be reduced

 and the air conditioner may stop running.

 Clean the air filter periodically,; otherwise cooling or heating performance will be reduced.

 Do not operate unit with horizontal louver in closed position.

Optimal operation

Operation Mode Selection

While simultaneously operating two or more indoor units, make sure the operation modes do not conflict 

with each other. The heat mode takes precedence over all other modes. If the unit initally started operating 

in heat mode, all other units can operate under heat mode only. For example: If the unit initially starts 

opearting under cool (or fan) mode, the other units can operate under any mode except heat. If one of the 

units selects heat mode, the other opearting units will stop opeartion and display PF (units with display 

window only) or the Auto and Operation indicator lights flash rapidly.

Operating Instructions (continued)

Summary of Contents for 2PAMSH18-MZ02

Page 1: ......

Page 2: ......

Page 3: ...ce technician or certified HVAC contractor for installation of this unit Contact an authorized service technician or certified HVAC contractor for repair or maintenance of this unit This appliance is...

Page 4: ...inlet and outlet vents Never attempt to repair relocate or modify the air conditioner yourself Always contact your qualified service provider if required Do not operate your air conditioner in a wet e...

Page 5: ...w the air conditioner to run for too long with the doors or windows open or if the humidity is very high If the air conditioner is to be used in conjunction with other heaters the air should be refres...

Page 6: ...amp For Cooling Heating models only Lights up when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation 1 Front panel 2 Top air in...

Page 7: ...ISPLAY PANEL OPERATION indicator The indicator flashes once every second after power is on and illuminates when the air conditioner is in operation TIMER indicator The indicator illuminates when TIMER...

Page 8: ...ication lamp This indicator appears only when the compressor is in operation and indicates the current operating frequency TIMER indication lamp Lights up during Timer operation DEFROST indication lam...

Page 9: ...cting pipe 11 Connective cable 12 Stop valve 13 Fan hood 10 11 12 13 Indoor unit 6 5 7 8 1 2 3 4 Air outlet Air inlet 1 Panel frame 2 Rear air intake grille 3 Front panel 4 Air filter behind 5 Horizon...

Page 10: ...hen the warm air control feature is activated in heating operation TIMER display Displayed during Timer operation TURBO operation display Displayed when select TURBO function on cooling operation or o...

Page 11: ...anual are for explanation purposes only Your air conditioner may be slightly different The actual shape shall prevail Indication lamp on LED Display window OPERATION indication lamp This lamp illumina...

Page 12: ...ting operation 1 Front panel 2 Air inlet 3 Air filter inside 4 Air outlet 5 Horizontal air flow grille outside 6 Horizontal air flow grille inside 7 Vertical air flow louver 8 Display panel 9 Manual c...

Page 13: ...ton is used to operate the unit temporarily in case you misplace the remote controlor its batteries are exhausted One press of the manual control button will lead to the forced AUTO operation If press...

Page 14: ...FAN indication lamp Lights up when the air conditioner starts defrosting automatically in heating operation applicable to cooling heating models only or fan only mode is selected applicable to coolin...

Page 15: ...rosting automatically in heating operation applicable to cooling heating models only or fan only mode is selected applicable to cooling only models 5 6 7 8 5 TEMPORARY button This button is used to op...

Page 16: ...2 4 3 OPERATION lamp This indicator illuminates when the unit is operational TIMER indication lamp Lights up during Timer operation ALARM indication lamp Flashes when malfunction occurs PRE DEF FAN in...

Page 17: ...unit will operate under forced COOL operation Close the panel firmly to its original position 1 3 2 NOTE The unit must be turned off before operating the manual control button If the unit is operation...

Page 18: ...er is connected to power initial power the horizontal louver may generate a sound for 10 seconds this is a normal operation CAUTION Range Range Vertical louver Adjust the air flow direction properly o...

Page 19: ...outlet parts sold separately are used with the indoor unit Heating To effectively heat the bottom of the room please set the louver downwards Cooling To effectively cool the whole room please adjust...

Page 20: ...peration 7 hours timer off 7 hours timer off To achieve optimal performance please note the following Adjust the air flow direction correctly so that it is not directed at occupants Adjust the tempera...

Page 21: ...ry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor unit Filter Handle Cleaning the air filter A clogged air filter reduces the cooling efficiency...

Page 22: ...HVAC contractor Check that the wiring is not broken off or disconnected Check that the air filter is installed Check if the air outlet or inlet is blocked after the air conditioner has not been used...

Page 23: ...ody must be disconnected before completely removing intake grille DUCT TYPE 2 Take out the air intake grille 3 Remove the air filter 4 Clean the air filter A vacuum cleaner or pure water may be used t...

Page 24: ...escape away from the flange fixed holes and take off the filter according to the arrow direction shows in Fig G2 3 Clean the air filter A vacuum cleaner or pure water may be used to clean the air fil...

Page 25: ...as just starting B Defrosting C Low temperature heating The indoor or outdoor fan stop running when defrosting Cooling and heating models only Defrosting Cooling and heating models only Frost may be g...

Page 26: ...gher Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed 8 Heating mode For cooling and heating models only The air conditioner draws in heat from the outdoor uni...

Page 27: ...ower cut Fuse may have blown Battery in Remote Control may be exhausted You have set a timer function Wait for power to be restored Replace the fuse Replace the battery Wait or cancel timer setting Se...

Page 28: ...erformance data is subject to change without notice Printed in China 844 472 2473 www perfectaire us PA Manual_Gen2MZMSOutdoorUser 01182018 Distributed by C L L e r i A t c e f r e P 5401 Dansher Rd C...