PARTS DIAGRAM

INSTALLATION HARDWARE

Before installing, please ensure you have all installation accessories included with this unit. (See list below.) If missing 

parts, please contact Consumer Services at 844-4PA-AIRE (844-472-2473). 

1. CABINET
2.  TOP RAIL
3.  SLIDING ACCORDION PANEL
4.  AIR INLET
5.  LOUVER DIRECTION ADJUSTMENT*
6.  FRESH AIR SWITCH
7.  FRONT GRILLE 

(Air filter is located behind 

the front grille)

8.  CONTROL PANEL
*  Changing Airflow Direction -  

Airflow on unit may be diverted left or 

right from center by louvers. Upward 

and downward air discharge is provided 

by tilting louvers. Adjust/tilt louvers for 

desired airflow direction.

NOTE: 

All of the illustrations in this manual 

are for explanation purposes only. Unit 

purchased may be slightly different.

ITEM

NAME OF PART

QTY

A

Foam Window Sash Seal

1

B

Window Lock Brackets

2

C

#10 x ¼

ʺ 

Pan-head Phillips Screws

6

D

#10 x ⅜

ʺ 

Pan-head Phillips Screws

3 or 7

E

#10 x ¾

ʺ 

Round-head Screws

6

F

#10 x ½

ʺ 

Pan-head Phillips Screws

3

G

Top Rail

1

H

Accordion Panels

2

I

Foam Seal

1

B

C

G

E F

A

H

D

I

1

2

5

7

6

3

4

8

Summary of Contents for 2PAHP12002

Page 1: ...WINDOW AIR CONDITIONER FOR MODEL 2PAHP12002 WITH HEAT PUMP Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...aintenance of this unit Contact an installer for installation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be...

Page 4: ...om the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so...

Page 5: ...d of time un plug or turn OFF main power switch Leaving power on may cause unit failure or fire DO NOT place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure o...

Page 6: ...tioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this unit When handling th...

Page 7: ...ging Airflow Direction Airflow on unit may be diverted left or right from center by louvers Upward and downward air discharge is provided by tilting louvers Adjust tilt louvers for desired airflow dir...

Page 8: ...must be outdoors not inside a building or garage Inner sill Offset Window Sill Exterior Interior wall 27 39 16 min Sash Check the location where the unit will be installed Proper installation is your...

Page 9: ...packing foam from inside of unit Handle NOTE Do not lift push pull or remove any expanded polystyrene foam from inside the air conditioner It is not packing material WARNING DO NOT operate unit with...

Page 10: ...and bottom slots of accordion Screw accordion to the top and bottom holes in air conditioner cabinet NOTE Some accordion panels may have 2 slots at each end You will be able to see a mounting hole thr...

Page 11: ...URING ACCORDION TO THE WINDOW FRAME 1 Pull left hand accordion panel out until it reaches the window frame Use a 3 32 drill bit to drill a starter hole through the hole in the accordion panel housing...

Page 12: ...out Condensate Drain Cup 1 2 Diameter Hose Outer Case 1 Insert air conditioner into cabinet 2 Install shipping screws on both sides of cabinet 3 Plug the control panel to the unit 4 Insert front tabs...

Page 13: ...crements up to 24 hours The TIMER ON OFF indicator will be on when the timer has been set TIMER OFF Turn the unit on to set the desired temp and fan speed Press the TIMER button Press the TEMP TIMER b...

Page 14: ...DO NOT place the remote where it is exposed to direct sunlight or strong lights DO NOT drop anything on the remote as this may cause damage DO NOT block the area between the unit and remote or it wil...

Page 15: ...can provide 2 watts of heat for every watt of electricity it consumes As outdoor temperatures drop the heating capacity and efficiency of the heat pump declines At temperatures below 45 F it is likely...

Page 16: ...ns within 5 seconds You can select 30 minute intervals from 30 minutes to 24 hours 3 Press the TIMER button again to confirm the setting The TIMER light on the control panel will be activated At the e...

Page 17: ...of the unit will be contaminated with dirt which may cause performance failure or damage to parts 4 Clean the air conditioner Use a soft dry cloth to wipe the air conditioner or use a vacuum cleaner t...

Page 18: ...struction Provide additional support for unit Water hitting fan blade Normal in high humidity Stop noise by removing drain plug or adding condensate drain cup Unit oversized for application compressor...

Page 19: ...remote control and the signal receiver on the unit Check the batteries in the remote UNIT BLOWS FUSES OR POPS CIRCUIT BREAKER Make sure there are enough available amps on the circuit for the air cond...

Page 20: ...Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_2PAHP...