![Perel TC78011LCD User Manual Download Page 5](http://html1.mh-extra.com/html/perel/tc78011lcd/tc78011lcd_user-manual_1528530005.webp)
TC78011LCD
V. 03
–
23/09/2021
5
©Velleman Group nv
3.
General Guidelines
Refer to the Velleman
®
Service and Quality Warranty on the last pages of this manual.
All modifications of the device are forbidden for safety reasons. Damage caused by user
modifications to the device is not covered by the warranty.
Only use the device for its intended purpose. Using the device in an unauthorised way will void
the warranty.
Damage caused by disregard of certain guidelines in this manual is not covered by the
warranty and the dealer will not accept responsibility for any ensuing defects or problems.
Nor Velleman Group nv nor its dealers can be held responsible for any damage (extraordinary,
incidental or indirect)
–
of any nature (financial, physical…) arising from the possession, use or
failure of this product.
Keep this manual for future reference.
4.
Technical Specifications
power supply .................................................................................. 220-240 V~, 50/60 Hz
power consumption ................................................................................................2500 W
Information requirements for electric local space heaters
Model identifier(s):
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage local space
heaters only (select one)
Nominal heat
output
P
nom
1,73
kW
manual heat charge control, with integrated
thermostat
N.A.
Minimum heat
output (indicative)
P
min
0,0
kW
manual heat charge control with room and/or
outdoor temperature feedback
N.A.
Maximum
continuous heat
output
P
max,c
2,428
kW
electronic heat charge control with room and/or
outdoor temperature feedback
N.A.
Auxiliary electricity consumption
fan-assisted heat output
N.A.
At nominal heat
output
el
max
0,002
kW
Type of heat output/room temperature control (select
one)
At minimum heat
output
el
min
N.A.
kW
single-stage heat output and no room
temperature control
no
In standby mode
el
SB
0,002
kW
two or more manual stages, no room
temperature control
no
with mechanic thermostat room temperature
control
no
with electronic room temperature control
yes
electronic room temperature control plus day
timer
no
electronic room temperature control plus week
timer
no