background image

 

Firefox 5CB (Clean Burn) 

DEFRA APPROVED FOR BURNING WOOD IN A SMOKE CONTORLLED AREA  

CE APPROVED.   

This appliance must be installed by a competent person and must 
comply with all building regulations including those referring to local 
authority by-laws, National and European Codes of Practice . Unless the 
installer is qualified to approve the installation, then approval must be 
sought from your local building control officer. It is an offence under UK 
law not to comply with this advice. After installation the appliance should 
be ready for use and instruction as to use and control given. 

Clean burn cast iron wood burning stove 

Installation & operating instructions.  To be left with user. 

FFXCB

 

01/10A

 

Summary of Contents for Firefox 5CB

Page 1: ...s National and European Codes of Practice Unless the installer is qualified to approve the installation then approval must be sought from your local building control officer It is an offence under UK...

Page 2: ...on of appliance including the stove pipe and use the operating tools provided The mitten provided is a tool Do not over fire it is possible to fire the stove beyond its design capacity This could dama...

Page 3: ...X 005 CB 1 21 Grate FFX 006 CB 1 22 Left Side Panel FFX036 CB 1 23 Side Brick FFX012 CB 1 24 Front Panel FFX035 CB 1 25 Secondary Air Duct FFX 024 CB 1 26 Top Brick Assembly FFX009 CB 1 Parts Assembly...

Page 4: ...Items Not Shown on Diagram 28 Glass Panel Seal FFX027 CB 1 29 Door Seal FFX026 CB 1 30 Operating tool FFX029 CB 1 31 Mitten FFX1 CB 1 32 Door Catch FFX017 CB 1 33 Door Glass Retaining Tabs FFX019 CB...

Page 5: ...ace opening can be bricked up or sealed with a register plate 2 5mm steel sheet or concrete A short length of flue pipe no smaller in diameter then the stove flue outlet or the manufacturer s stated f...

Page 6: ...hs and combustion air supplies are in accordance with the current Building Regulations Local Authority Bye Laws British Standards and Codes of Practice The Firefox 5 CB has no ventilation requirement...

Page 7: ...panels could be dislodged Lighting the stove We recommend that you have two or three small fires before you operate your stove to its maximum heat output This is to allow the paint to cure and casting...

Page 8: ...shing is only required when excessive amounts of ash have built up The grate has two positions open or closed The open position is for de ashing only To de ash open grate with control knob scrape ash...

Page 9: ...m riddling rod rotate grate anti clockwise until rod passes out of guide hole Now manipulate grate out of stove door opening Note the position of the hook on the end of the riddling rod as it connects...

Page 10: ...rn glass clean C If glass requires cleaning use glass cleaner recommended by your supplier only use glass cleaner or cold glass DO NOT USE any abrasives or scrapers as these will scratch glass causing...

Page 11: ...Installation Diagrams Typical Top Flue Installation using steel closure plate incorporating clean out door for chimney sweeping...

Page 12: ...tion Diagrams Typical Installation For Inglenook Fireplaces Inglenook fireplaces can have very large bore chimneys Check with your installer you may need stainless steel flexible liner for solid fuel...

Page 13: ...Installation Diagrams Typical Installation Into In Filled Masonry Fireplaces...

Page 14: ...Nominal Heat Output kW 4 9 Efficiency 72 Flue Gas Temp C 313 Refuel Period Hour 1 Sides mm 450 Safe Distance to Combustibles Rear mm 400 Flue Outlet Size mm 125 g s 5 1 Flue Gas Mass Flow 0 36 CO emi...

Reviews: