5  DESIGN AND OPERATION 

5.1  Main features 

The gate meets current requirements to such equipment in compliance with 

 

GOST P 51241. Main features of the gate are as follows: 

  possibility of 

remote

 gate unlocking;

 

 

leaf reset 

by a hydraulic door closer after the passage;

 

 

wide passageway 

to provide controlled passage for people in wheelchairs

 

(with an 

attendant) and deliveries of large or bulky items; 

 

low-weight leaf 

for comfortable passage;

 

  aluminium-alloy structure with

  high resistance to corrosion 

guarantees long life 

operation even in unfavourable environments;

 

 

durable polymeric powder coating 

protects the outside appearance; 

 

unity of design 

with 

RTD-15

  full height turnstiles and 

MB-15

  railings enables 

various configurations of the entrance point to meet any required layout and 
dimensions; 

  together with 

RTD-15

 full height turnstiles, the gate can be used as an 

emergency 

exit

5.2  Design and operation 

The gate design is shown in Fig. 1. 

Unless noted otherwise, the position numbers in the Manual agree with Fig.1. 

Overall dimensions of the gate are given in Fig. 2. 

The gate consists of: 

 

a frame (1)

  a leaf (2); 

  an electric lock (3); 

  a door closer (4). 

The 

frame 

(1) consisting of three joined vertical posts and 

the leaf

 

(2) are made of durable 

aluminium profile. The assembled gate is delivered with the 

rim

 

electric lock

 (3) mounted 

on the frame. During the installation, the hydraulic 

door closer 

(4) is mounted on the frame 

and the leaf. The gate is mounted on the floor with anchor bolts driven through four 
mounting holes in the post flanges. 

In the 

home position 

the leaf provides complete closure of the passageway between the 

posts. The leaf opens towards the door closer. Mounting holes for the door closer are 
made for opening angle of 120°, according to its installation and operation instructions. 

The gate 

reset state is 

«closed for entrance and exit» (the leaf is in the home position, the 

lock is locked up). 

Unlocking 

is made by ether a mechanical key or a control pushbutton on the lock body. 

Locking 

is made by automatic latching of the lock when the leaf returns to the home 

position. (See the installation and operation instructions for the electric lock).  

For remote unlocking the lock should be wired to a 12V DC @ 3A power supply unit as per 
the lock operation instructions through the cabling hole in the gate post.  

 

Summary of Contents for WHD-15

Page 1: ...INSTALLATION AND OPERATION MANUAL WHD 15 Full Height Security Gate...

Page 2: ...Full Height Security Gate W WH HD D 1 15 5 Installation and Operation Manual...

Page 3: ...ipment and mounting hardware 4 5 DESIGN AND OPERATION 5 5 1 Main features 5 5 2 Design and operation 5 6 MARKING AND PACKAGING 8 7 SAFETY REQUIREMENTS 8 8 INSTALLATION 9 8 1 Main guidelines 9 8 2 Inst...

Page 4: ...and areas with high security requirements and necessity for full vertical closure of the passageway It is advisable to determine the number of the gates sufficient for fast and convenient pedestrian...

Page 5: ...delivery set on request 15 full height railing sections 1 Fasteners 2 SORMAT PFG IR 12 20 anchor bolts 3 4 Note Technical characteristics of optional equipment are given in the respective documentati...

Page 6: ...f the gate are given in Fig 2 The gate consists of a frame 1 a leaf 2 an electric lock 3 a door closer 4 The frame 1 consisting of three joined vertical posts and the leaf 2 are made of durable alumin...

Page 7: ...Installation and Operation Manual 6 Fig 1 General view of the WHD 15 gate 1 frame 2 leaf 3 electric lock 4 door closer Fig 2 Overall dimensions of the WHD 15 gate...

Page 8: ...s it goes and press the control pushbutton If after that the key is put out the next unlocking can be made without the key by pressing of the control pushbutton If the key is turned clockwise as far a...

Page 9: ...lation of the gate should be carried out by qualified personnel ONLY in strict accordance with this Manual and general safety requirements for electrical and installation work In the course of the ins...

Page 10: ...ess deviation must not exceed 1 5 mm using relevant mounting hardware for installation on different foundations following guidelines of the door closer installation and operation instructions during i...

Page 11: ...ng screws see installation and operation instructions for the door closer 8 3 Installation of standard and optional equipment Seamless integration and unity of design with the RTD 15 series full heigh...

Page 12: ...ons DO NOT subject the gate to strong impact DO NOT clean the gate with substances that may cause damage or corrosion of its parts 9 TRANSPORTATION AND STORAGE The gate in the original package should...

Page 13: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Page 14: ...www perco com...

Reviews: