Operation manual
22
In the “Single passage in the set direction” mode the turnstile will close automatically after a
person’s passage in the set direction. The turnstile will also close automatically, if the passage is
not made within 5 sec. In the “Bidirectional single passage” mode after the passage in one
direction the countdown of the passage waiting time (5 sec) for the opposite direction is
recommenced.
9.3 Operating modes of the turnstile at potential control mode
See Table 3 for the operating modes set with the RC-panel. Setting the operating modes for each
direction is independent, i.e. setting the operating mode for one direction does not change the
operating mode set earlier for the opposite one.
Table 3 Potential control mode (the jumper is taken off from the connector J1)
№
The turnstile
operating
modes
Actions to do
Indication
on the RC
Indication on
the turnstile
Response to the
barrier arm turning
1
Both directions
are closed (the
turnstile is
blocked both
for entry and
exit)
The high level is
on contacts
Unlock A and
Unlock B or low
level on the
contact Stop
The red
indicator
above the
STOP
button
is on
The two “Red
cross”
pictograms (left
and right) are on
2
One of the
passage
directions is
open (the
turnstile is
open for
passage in the
set direction)
The low level is on
the contact
corresponding to
the passage
direction, the high
level is present on
the other contacts
The green
indicator
above the
button of the
chosen
passage
direction is
on
The “Green
arrow” pictogram,
showing the
passage
direction, and the
“Red cross”
pictogram from
the opposite side
are on
If by the moment of
passing through the
turnstile the low level is
present on the contact
corresponding to the
set passage direction,
the turnstile remains
open in the set direction
3
Both passage
directions are
open (the
turnstile is
open for
passage in
both
directions)
The low level is on
the contacts
corresponding to
the both
directions, the high
level is on the
contact Stop
The two
green
indicators
(left and
right) are on
The two “Green
arrow”
pictograms (left
and right) are on
If by the moment of
passing through the
turnstile the low level is
present on the contact
corresponding to the
set passage direction,
the turnstile remains
open in the set direction
For the ACS outputs note the following:
High level — contacts of the output relay are broken or the output transistor
is closed.
Low level — contacts of the output relay are closed or the output transistor
is open.
9.4 Actions in emergency
For urgent evacuation of people from business facilities in case of fire, natural calamities or other
emergencies, the additional emergency exit should be provided. The anti-panic barrier section of
rotary type can be used as an emergency exit.
The additional emergency exit can be provided by the turnstiles equipped with anti - panic drop
arms. The anti - panic drop arms allow to set the passageway free without any special keys or
tools. To drop the anti - panic arm down just pull out the arm towards its axis direction, until the
rotation mechanism becomes free, and then turn the arm down (see Fig. 14).