For installers and professionals
- 15 -
function. When starting the heat pump, the fan will start to run in 3 minutes, in another
30 seconds, the compressor will start to run.
After pool heat pump starts up, check for any abnormal noise from the heat pump.
Check the temperature setting
2.4. Maintenance and winterizing
2.4.1 Maintenance
The maintenance should be carried out once per year by qualified professional
technician.
Cut off power supply of the
heat pump before cleaning,
examination and repairing .
Do not touch the electronic
components until the LED
indication lights on PCB turn off.
Please clean the evaporator with household detergents or clean water, NEVER use
gasoline, thinners or any similar fuel.
Check bolts, cables and connections regularly.
2.4.2 Winterizing
In winter season when you don’t swim, please cut off power supply and drain water out of the heat
pump. When using the heat pump under 2℃, make sure there is always water flow.
3. Trouble shooting for common faults
Failure
Reason
Solution
Heat pump doesn’t
run
No power
Wait until the power recovers
Power switch is off
Switch on the power
Fuse burned
Check and change the fuse
The breaker is off
Check and turn on the breaker
Fan running but with
insufficient heating
evaporator blocked
Remove the obstacles
Air outlet blocked
Remove the obstacles
3 minutes start delay
Wait patiently
Display normal, but no
heating
Set temp. too low
Set proper heating temp.
3 minutes start delay
Wait patiently
If above solutions don’t work, please contact your installer with detailed information and your model
number. Don’t try to repair it yourself.
ATTENTION
!
Please don’t try to repair the heat pump by yourself to avoid any risk.
Important:
Unscrew the water union of inlet pipe
to let the water flow out.
When the water in machine freezes in
winter season, the titanium heat
exchanger may be damaged.
Summary of Contents for 7301269
Page 1: ...DE EN ...
Page 20: ...Für Monteure und Händler 18 Anhang 1 Schaltplan für Heizprioritätsfunktion Optional ...
Page 21: ...Für Monteure und Händler 19 Anhang 2 Schaltplan für Heizprioritätsfunktion Optional ...
Page 29: ...DE EN ...
Page 47: ...For installers and professionals 17 Appendix 1 Heating priority wiring diagram Optional ...
Page 48: ...For installers and professionals 18 Appendix 2 Heating priority wiring diagram Optional ...
Page 56: ...Version E67XVr32 ...