Ultrasonic sensor

UC4000-L2-E4-V15

<

Sensor head bidirectional and rotatable

<

Function indicators visible from all directions

<

Quick mounting bracket

<

Selectable sound lobe width

<

Programmable

Single head system

 

 

Dimensions

LED ye

LED gn

LED ye

LED gn

3

7

M1

2

 x 

1

2

8

67

40

2

0

3

0

4

0

5.5

ø 5.5

46

60

T

o

u

t

p

w

r

4

0

Technical Data

General specifications

Sensing range

200 ... 4000 mm

Adjustment range

240 ... 4000 mm

Dead band

0 ... 200 mm

Standard target plate

100 mm x 100 mm

Transducer frequency

approx. 85 kHz

Nominal ratings

Response delay

minimum: 110 ms
factory setting: 280 ms

Time delay before availability

t

v

≤ 1600 ms

Indicators/operating means

1

Release

da

te:

2021-03-

-

05

 Date

 of

Release

 date:

 2021-03-05

 Date

 of

 issue:

 2021-03-05

 Filename:

 277771_eng.pdf

Germany: +49 621 776 1111

Fuchs Group

Refer to "General Notes Relating to Fuchs Product Information".

USA: +1 330 486 0001

Singapore: +65 6779 9091

www.pepperl-fuchs.com

[email protected]

[email protected]

[email protected]

Summary of Contents for UC4000-L2-E4-V15

Page 1: ...240 4000 mm Dead band 0 200 mm Standard target plate 100 mm x 100 mm Transducer frequency approx 85 kHz Nominal ratings Response delay minimum 110 ms factory setting 280 ms Time delay before availabi...

Page 2: ...op Ud 2 V Repeat accuracy 0 1 of full scale value Switching frequency f 2 8 Hz Range hysteresis H programmable preset to 1 mm Temperature influence 1 5 of full scale value Compliance with standards an...

Page 3: ...accordance with EN 60947 5 2 brown white blue black gray Characteristic Curve 0 1000 2000 3000 4000 5000 6000 2000 1500 1000 500 0 500 1000 1500 X Y Characteristic response curve Distance X mm Distan...

Page 4: ...rasonic sensor UC4000 L2 E4 V15 Release date 2021 03 05 Date of issue 2021 03 05 Filename 277771_eng pdf 4 Germany 49 621 776 1111 Pepperl Fuchs Group Refer to General Notes Relating to Pepperl Fuchs...

Page 5: ...Button for 2 s yellow LED flashes 3 Press the Programming Button for 2 s green LED flashes three times for confirmation The sensor returns to normal operation Programming Switch Points by using the P...

Page 6: ...below If the synchronization input goes to a high level for 1 second the sensor will switch to standby mode indicated by the green LED In this mode the output s will remain in the last valid output s...

Page 7: ...input switches the sensor to standby mode if it is parameterized for external synchronization Note Sensor response times will increase proportionally to the number of sensors that are in the synchron...

Reviews: