background image

20

21

-1

1

16

Power Supply PS1000-D2-24.40.RM

Front Side and User Elements

10

Front Side and User Elements

Figure 10.1 Front side

1 Output terminals 

(screw terminals)

2 Chassis-ground terminal

 

To be connected on the top side 

of the housing with a ring-type terminal 

(ring cable lug) which is suitable for a M4 

screw. 

Connection of the chassis is optional and 

not required since the unit fulfills the 

requirements according to protection class III.

3 Input terminals for input 1 

(screw terminals)

4 Input terminals for input 2 

(screw terminals)

PS1000-D2-24.40.RM

Part No. 70103528

DC 12-28V 40A

OUTPUT

Redundancy Module

Input 1

DC 12-28V

20A

Input 2

DC 12-28V

20A

Chassis

Ground

3

4

2

2

1

Summary of Contents for PS1000-D2-24.40.RM

Page 1: ...ISO9001 PS1000 D2 24 40 RM Redundancy Module Technical Information ...

Page 2: ...sion as well as the supplementary clause Expanded reservation of proprietorship Worldwide Pepperl Fuchs Group Lilienthalstr 200 68307 Mannheim Germany Phone 49 621 776 0 E mail info de pepperl fuchs com North American Headquarters Pepperl Fuchs Inc 1600 Enterprise Parkway Twinsburg Ohio 44087 USA Phone 1 330 425 3555 E mail sales us pepperl fuchs com Asia Headquarters Pepperl Fuchs Pte Ltd P F Bui...

Page 3: ...ristics 11 6 Power Losses 12 7 Lifetime Expectancy and MTBF 13 8 Terminals and Wiring 14 9 Functional Diagram 15 10 Front Side and User Elements 16 11 EMC 17 12 Environment 18 13 Protection Features 19 14 Safety Features 20 15 Dielectric Strength 21 16 Approvals And Fulfilled Standards 22 17 Regulatory Compliance 23 18 Physical Dimensions and Weight 24 19 Application Notes 25 ...

Page 4: ...Power Supply PS1000 D2 24 40 RM Contents 4 2021 11 ...

Page 5: ... this information does not represent a warranty in the legal sense of the word As the state of our knowledge and experience is constantly changing the information in this data sheet is subject to revision We therefore kindly ask you to always use the latest issue of this document available under www pepperl fuchs com No part of this document may be reproduced or utilized in any form without our pr...

Page 6: ...ery disregarding whether it is full 13 7V or flat 10V 24Vdc A figure with the unit Vdc at the end is a momentary figure without any additional tolerances included may A key word indicating flexibility of choice with no implied preference shall A key word indicating a mandatory requirement should A key word indicating flexibility of choice with a strongly preferred implementation 1 1 Redundancy Use...

Page 7: ...el to provide continued operation following most failures in a single power supply All power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements E g To achieve a 40A redundant system five 10A power supplies are needed in a N 1 redundant system AC DC AC DC AC DC AC DC AC DC AC DC IN1 OUT IN2 IN1 OUT IN2 IN1 OUT IN2 Load ...

Page 8: ...ion The device is a redundancy module for building redundant power supply systems The device is equipped with 2 inputs and 1 output Power supplies with an output current of up to 20 A and one output can be connected to the inputs The power supplies can transmit a rated current of up to 40 A and 40 A to 65 A for 5 s The both inputs are decoupled by MOSFETs This reduces heat generation and voltage d...

Page 9: ...strands of a stranded wire enter the terminal connection Unused screw terminals should be securely tightened The device is designed for pollution degree 2 areas in controlled environments No condensation or frost is allowed The enclosure of the device provides a degree of protection of IP20 The input must be powered from a PELV or SELV source or an Isolated Secondary Circuit in order to maintain a...

Page 10: ...duct datasheet for use above 2000m 6560ft Keep the following minimum installation clearances 40mm on top 20mm on the bottom 5mm left and right side Increase the 5mm to 15mm in case the adjacent device is a heat source When the device is permanently loaded with less than 50 the 5mm can be reduced to zero Under special circumstances clearances can be reduced See details in the product datasheet The ...

Page 11: ...onds max 2x 13A in overload voltage 6V or short circuit mode Peak input current max 1000A for max 1ms per input Output current nom 40A continuous nom 40 65A for 5 seconds max 26A in overload voltage 6V or short circuit mode Reverse current max 1mA at 24V per input 40 C to 70 C Reverse voltage max 40Vdc voltage applied to the output continuously allowed Output capacitance typ 320µF Voltage Drop typ...

Page 12: ... 23W at no output current both inputs are connected to input voltages P ower Losses typ 0 0 5 10 30 1 0 2 0 4 0 5 0 7W 40A 25 15 20 35 Output C urrent A 3 0 A 25 C B 60 C 6 0 B Output V A Power supply 24V 20A s et to 24 5V V A I1 I2 U1 U2 A V IOUT UOUT I1 I2 U2 U1 Los s es U1 UOUT I1 U2 I2 IOUT Power supply 24V 20A s et to 24 5V Variable Load 0 40A PS1000 D2 24 40 RM Input 1 Input 2 Output P ower ...

Page 13: ...round Fixed GF25 24V and 25 C 1 588 000h 1 457 000h Ground Benign GB40 24V and 40 C 2 159 000h 1 964 000h Ground Benign GB25 24V and 25 C 1 The Lifetime expectancy shown in the table indicates the minimum operating hours service life and is determined by the lifetime expectancy of the built in electrolytic capacitors Lifetime expectancy is specified in operational hours and is calculated according...

Page 14: ...ion codes and installation regulations 4 Ensure that all strands of a stranded wire enter the terminal connection 5 Screws of unused terminal compartments should be securely tightened 6 Ferrules are allowed 7 Do not connect or disconnect the wires from the terminals below 25 C 13 F Input Output Type Screw termination IP20 Finger safe construction Suitable for field installation Screw termination I...

Page 15: ...Power Supply PS1000 D2 24 40 RM Functional Diagram 2021 11 15 9 Functional Diagram Figure 9 1 Functional diagram Input 1 control control Input 2 C hassis Ground Output ...

Page 16: ...ith a ring type terminal ring cable lug which is suitable for a M4 screw Connection of the chassis is optional and not required since the unit fulfills the requirements according to protection class III 3 Input terminals for input 1 screw terminals 4 Input terminals for input 2 screw terminals PS1000 D2 24 40 RM Part No 70103528 DC 12 28V 40A OUTPUT Redundancy Module Input 1 DC 12 28V 20A Input 2 ...

Page 17: ...0 4 8 50Hz 30A m Criterion A 1 A test is not applicable according to EN 61000 6 2 since the device does not contain components susceptible to magnetic fields e g hall elements electrodynamic microphones etc Criterion A Redundancy module shows normal operation behavior within the defined limits EMC Emission According to generic standards EN 61000 6 3 and EN 61000 6 4 Conducted emission IEC CISPR 16...

Page 18: ...e de rating 2 5A 1000m or 5 C 1000m 2000m 6500ft see Figure 12 2 Over voltage category not applicable The concept of the overvoltage category is used for equipment energized directly from the low voltage mains IEC 60664 1 4 3 3 2 1 Degree of pollution 2 IEC 62103 EN 50178 not conductive 1 Operational temperature is the same as the ambient or surrounding temperature and is defined as the air temper...

Page 19: ...put polarity protection included unit does not start when input voltage is reversed Degree of protection IP 20 EN IEC 60529 Penetration protection 3 6mm e g screws small parts Over temperature protection not included Input transient protection not included Output transient protection included see EMC section Internal input fuse not included ...

Page 20: ... Features 14 Safety Features Input output separation no galvanic separation Mosfet between input and output Class of protection III PE Protective Earth or chassis connection not required PE resistance 0 1Ohm between housing and chassis ground terminal ...

Page 21: ...acturer Field tests may be conducted in the field using the appropriate test equipment which applies the voltage with a slow ramp 2s up and 2s down Connect input output terminals together before conducting the test When testing set the cut off current settings to the value in the table below Figure 15 1 Dielectric strength A Type test 60s 500Vac Factory test 5s 500Vac Field test 5s 500Vac Cut off ...

Page 22: ...ical Equipment for Measurement Control and Laboratory Use Particular requirements for control equipment Applicable for US and Canada E File E223176 EN 60079 0 2012 A11 2013 EN 60079 7 2016 EN 60079 15 2010 ATEX certificate EPS 11 ATEX 1312 X ATEX marking e II 3G Ex ec II T4 Gc IEC 60079 0 2011 IEC 60079 7 2015 IEC 60079 15 2010 IECEx certificate IECEx EPS 20 0057X IECEx marking Ex ec IIC T4 Gc ...

Page 23: ...tive LVD RoHS directive WEEE Directive Manufacturer s Statement EU Regulation on Waste Electrical and Electronic Equipment Registered in Germany as business to business B2B products REACH Directive Manufacturer s Statement EU Regulation regarding the Registration Evaluation Authorization and Restriction of Chemical EAC TR Registration EAC Certificate EAC EurAsian Conformity Registration Russia Kaz...

Page 24: ...ight 124mm 4 88 inch Depth 127mm 5 0 inch The DIN mounting rail height must be added to the unit depth to calculate the total required installation depth Weight 280g 0 62lb DIN mounting rail Use 35mm DIN mounting rails according to EN 60715 or EN 50022 with a height of 7 5 or 15mm Housing material Body Aluminium alloy Cover galvanized steel Installation istructions See chapter 4 36 ...

Page 25: ...e loads 19 3 Sideward Installation Clearances The minimum clearance recommendations are defined in chapter 4 Normally the following installation clearance are recommended 40mm on top 20mm on the bottom 5mm on the left and right sides when the device is loaded permanently with more than 50 of the rated power Increase this clearance to 15mm in case the adjacent device is a heat source e g another po...

Page 26: ... 60A output current 20A Load F ailure Monitor LNP E P ower S upply DC OK R edundancy Module Output Input 1 Input 2 LNP E P ower S upply DC OK L P E I I N PS1000 D2 24 40 RM Note Use separate mains systems for each power supply whenever it is possible F ailure Monitor LNP E P ower S upply DC OK R edundancy Module Output Input 1 Input 2 LNP E P ower S upply DC OK LNP E P ower S upply DC OK R edundan...

Page 27: ...Max allowed output current results in approximately half the lifetime expectancy of A1 Figure 19 4 Mounting orientation A standard orientation Figure 19 5 Mounting orientation B upside down Figure 19 6 Mounting orientation C table top mounting Figure 19 7 Mounting orientation D horizontal cw R edundancy Module OUTP UT INP UTS Output C urrent 0 10 20 30 40 60 C 10 20 30 40A 50 A1 Ambient Temperatur...

Page 28: ... Power Supply PS1000 D2 24 40 RM Application Notes Figure 19 8 Mounting orientation E horizontal ccw R edundancy Module OUTP UT INP UTS Output C urrent 0 10 20 30 40 60 C 10 30 40A 50 20 A1 A2 Ambient Temperature ...

Page 29: ...Power Supply PS1000 D2 24 40 RM Notes 2021 11 29 ...

Page 30: ...Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www pepperl fuchs com Pepperl Fuchs Subject to modifications Printed in Germany DOCT 7829 ...

Reviews: