background image

PMI360DV-F130-IU2E2-

V15

Inductive angle positioning 

system

FACTORY AUTOMATION

MANUAL

Summary of Contents for PMI360DV-F130-IU2E2-V15

Page 1: ...PMI360DV F130 IU2E2 V15 Inductive angle positioning system FACTORY AUTOMATION MANUAL...

Page 2: ...of Delivery for Products and Services of the Electrical Indus try published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its mos...

Page 3: ...cessories 10 4 4 1 Connecting cable 10 4 4 2 Actuator 10 5 Installation 11 5 1 Note on safety 11 5 2 Mounting 11 5 3 Electrical connection 13 6 Commissioning 14 6 1 Programming the switching outputs 1...

Page 4: ...4 PMI360DV F130 IU2E2 V15 9 Troubleshooting 21 9 1 Faults when programming the outputs 21 9 2 Faults during operation 22 10 Disposal 23...

Page 5: ...gy on a worldwide scale Symbols used The following symbols are used in this manual Handling instructions You will find handling instructions beside this symbol Contact If you have any questions about...

Page 6: ...developed and manufactured under observance of the applicable European standards and guidelines The product manufacturer Pepperl Fuchs GmbH D 68307 Mannheim has a certified quality assurance system t...

Page 7: ...e performed by a trained professional only User modification and or repair are dangerous and will void the warranty and exclude the manufacturer from any liability If serious faults occur stop using t...

Page 8: ...s an analog output for the indication of angular positions For high resistance loads 3 3 k the angular position will output a voltage value 0 10 V DC and for low resistance loads 400 a current value 4...

Page 9: ...e the start and end points of the analog output and the outer S1 and S2 buttons are used to configure the start and end of the detection zone of the two switching outputs on the sensor The S1 S2 and I...

Page 10: ...at may be used in electrically noisy installation environments 4 4 2 Actuator The BT F130 A actuator is designed for mounting directly on the drive shaft or a servodrive Figure Material Length Order d...

Page 11: ...ctuator The actuator must not make physical contact or scratch the sensors surface when moving Using a different actuating element You may use a different actuator instead of the BT F130 A actuator pr...

Page 12: ...inner surface E Sensor F Insert the shaft until actuator C and the sensitive surface on sensor D overlap as far as possible Dimension Value t 2 mm w 7 5 mm d1 Depending on the drive shaft material S23...

Page 13: ...4 Check that the wires are connected correctly before connecting the cordset to the sensor On Pepperl Fuchs cordsets the wire colors are assigned to the connecting pins in the connector according to...

Page 14: ...he device is ready for you to teach in the signaling zone end point 5 Move the actuator to the position that you wish to define as the signaling zone end point The rotation direction of the actuator i...

Page 15: ...The yellow I U LED lights up for 2 seconds and then starts to flash again This indicates that the device is ready for you to teach in the end point of the analog ramp 4 Move the actuator to the posit...

Page 16: ...If you intend to program an angle segment of exactly 360 for the analog output you can make use of the restriction that prevents the angle segment from exceeding 360 In the second step of the angle se...

Page 17: ...tion of the second switching point of switching output S2 example 310 6 Start position of analog output S3 example 20 7 End position of analog output S3 example 110 8 Angular range outside of analog m...

Page 18: ...ry The start and end points of the analog measuring range can be defined by programming each relevant angular position the only restriction being that the analog measurement range must fall between 45...

Page 19: ...ctuator leaves the detection range of the angular positioning system e g actuator is removed the function of the output depends on whether the analog output assumes the function of a voltage or a curr...

Page 20: ...he associated yellow LED starts to flash slowly after 2 seconds 2 Continue to hold the sensor button The LED begins to flash more quickly after an additional 10 seconds 3 Then release the button withi...

Page 21: ...actuator mounted too far away from the surface of the sensor Mount actuator according to specifications see chapter 5 2 Power Error LED lights up red during programming Actuator lost during the param...

Page 22: ...3 6 mA No actuator in the detection area of the sensor or unreliable detection of the actuator Check that the actuator used is mounted correctly or install an actuator with appropriate dimensions at...

Page 23: ...osal Electronic waste is hazardous waste When disposing of the equipment observe the current statutory requirements in the respective country of use as well as local regulations The device does not co...

Page 24: ...hs GmbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Pa...

Reviews: