Communication via EtherNet/IP
2
0
2
0
-1
2
49
Angle data: Angle (ID 104)
The following default settings apply:
•
The value is output in the set resolution of the device.
Position Data X: Position Value Unsigned (ID 105)
The following default settings apply:
•
The value is output in the resolution set for the device.
•
If the ERR bit is set in the "Status word (ID 100)" attribute, the error number is transferred
to this attribute.
Position Data Z: Z Distance (ID 106)
The following default settings apply:
•
The value is output in the resolution set for the device.
Size
Type
Content
2 byte consistent Input data
16 bit angle data
LSB first
LSB = least significant byte
Resolution: 0.1
°
, 1
°
binary coded
Size
Type
Content
4 byte consistent Input data
32 bit X data
LSB first
LSB =
l
east
s
ignificant
b
yte
Resolution: 0.1 mm, 1 mm, 10 mm, binary coded
At a resolution of 1 mm and 10 mm: L
max =
10.00 km =
10,000,000 mm
Size
Type
Content
2 byte consistent Input data
16 bit Z data
LSB first
Resolution: 0,1 mm, 1 mm, 10 mm, binary coded