5.2.2

Connection via RS 232

Connecting RS 232 connecting cable to computer

1. Power off the computer.

2. Connect the RS 232 plug of the connecting cable to the RS 232 port of the computer.

3. Connect the low-voltage plug of the power-supply unit to the low-voltage jack of the 

RS 232 connecting cable.

4. Connect the mains power plug of the power-supply unit to the mains power supply.

5. Power on the computer.

The handheld turns itself on automatically once you have turned the computer on.

6. Scan the code 

RS 232 1 Way Mode

:

7. Scan the code 

Save Settings

:

The handheld uses the following RS 232 factory settings:

RS 232 1 Way Mode

57600 baud

2 stop bits

8 data bits

No parity

Further RS 232 configuration options, see chapter 7.3.2.

Summary of Contents for ODT-HH-MAH120-HD

Page 1: ...ODT HH MAH120 HD ODT HH MAH120 WH HD HANDHELD HIGH DENSITY FACTORY AUTOMATION MANUAL ...

Page 2: ...ivery for Products and Services of the Electrical In dustry published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its most recent version as well as the supplementary clause Expanded reservation of proprietorship ODT HH MAH120 HD ODT HH MAH120 WH HD ...

Page 3: ...Disposal 7 4 Product description 8 4 1 ODT HH MAH120 HD use and application 8 4 2 Field of vision and resolution 8 4 3 Indicators and control elements 9 4 4 Accessories 10 4 4 1 Connecting cable 10 5 Installation 11 5 1 Preparation 11 5 2 Connection 11 5 2 1 Connection via USB 12 5 2 2 Connection via RS 232 13 5 2 3 Connection via PS 2 14 6 Commissioning 15 6 1 Positioning and reading techniques 1...

Page 4: ... PDF417 21 7 1 18 Pharmacode 22 7 1 19 Post Codes 22 7 1 20QR Code 23 7 1 21GS1 data bar 23 7 1 22Telepen 24 7 1 23UPC EAN JAN 24 7 2 Optimization of the decoding performance 25 7 2 1 Reading high density data matrix codes 25 7 3 Handheld configuration 26 7 3 1 USB operating modes 27 7 3 2 RS 232 operating modes 28 7 3 3 Volume and vibration setting 29 7 3 4 Configuration of LED target projection ...

Page 5: ... chapters Cable connection see chapter 5 2 Basic operation see chapter 6 Optimization and configuration of handheld see chapter 7 Symbols used The following symbols are used in this manual Handling instructions You will find handling instructions beside this symbol Contact If you have any questions about the device its functions or accessories please contact us at Pepperl Fuchs GmbH Lilienthalstra...

Page 6: ...product was developed and manufactured under observance of the applicable European standards and guidelines The product manufacturer Pepperl Fuchs GmbH D 68307 Mannheim has a certified quality assurance system that conforms to ISO 9001 Note A Declaration of Conformity can be requested from the manufacturer ISO9001 ...

Page 7: ...ngerous and will void the warranty and exclude the manufacturer from any liability If serious faults occur stop using the device Secure the device against inadvertent operation In the event of repairs return the device to your local Pepperl Fuchs representative or sales office When packing the device for storage or transport use materials that will protect the device from bumps and impacts and pro...

Page 8: ...ifficult ambient conditions is made easier by the sturdy design of the MAH120 HD which can withstand a fall from a height of 2 m onto a solid floor ground without its functions being impaired Confirmation of a successful reading is effected by optical acoustic or tactile means vibration USB PS 2 or RS 232 is available as the standard interface depending on which connecting cable you choose You can...

Page 9: ...Action Tactile acoustic signal LED handheld successfully switched on 1 signal tone vibration Flashes yellow green yellow Connection using USB connecting cable successful 1 signal tone vibration Reading successful data have been sent to the computer 1 signal tone vibration Flashes green Configuration code successfully read configuration performed 1 signal tone vibration Short break 1 signal tone vi...

Page 10: ...llowing connecting cables are available as an option Designation Description ODZ MAH CAB B14 Connecting cable USB interface length approx 180 cm ODZ MAH CAB B14 3 7m Connecting cable USB interface length approx 370 cm ODZ MAH CAB R2 Connecting cable RS 232 interface length approx 120 cm ODZ MAH CAB R6 Connecting cable PS 2 interface length approx 120 cm ...

Page 11: ... the shipping documents If you have any questions please contact Pepperl Fuchs 3 Keep the original packing material in case you need to store or ship the unit at a later time 5 2 Connection You have the opportunity to connect the handheld to the following PC interfaces USB RS 232 PS 2 Attaching the connecting cable to the handheld 1 Slide the protective cap over the 8 pin DIN plug 2 Align the 8 pi...

Page 12: ...onnection via USB Connecting USB connecting cable to computer 1 Insert the USB plug of the connecting cable in a free USB port on your computer This can be done during operation The handheld turns itself on automatically once you have connected it to the computer 2 Scan the code USB Keyboard Mode 3 Scan the code Save Settings Further USB configuration options see chapter 7 3 1 ...

Page 13: ...wer supply unit to the low voltage jack of the RS 232 connecting cable 4 Connect the mains power plug of the power supply unit to the mains power supply 5 Power on the computer The handheld turns itself on automatically once you have turned the computer on 6 Scan the code RS 232 1 Way Mode 7 Scan the code Save Settings The handheld uses the following RS 232 factory settings RS 232 1 Way Mode 57600...

Page 14: ... USB keyboard connect the keyboard with an appropriate adapter to the PS 2 connecting jack of the connecting cable If you are using a keyboard with PS 2 plug connect the plug directly to the PS 2 connecting jack of the connecting cable 4 Connect the PS 2 plug of the connecting cable to the computer s PS 2 port for keyboards 5 Power on the computer The handheld turns itself on automatically once yo...

Page 15: ...all codes or codes with a high information density Sighting and reading 1D and 2D codes 1 With the trigger button pressed aim the red square at the code to be read 2 Alter the distance between the handheld and the code depending on the position of the green square the code is optimally sighted as soon as the two squares overlap The code is read automatically In the event of successful decoding the...

Page 16: ...7 1 1 Aztec Example 7 1 2 Codabar Example 7 1 3 Codablock F Example Note Code Save Settings Always scan the code Save Settings after reading a configuration code Thus the configuration code is saved permanently Aztec On Aztec Off Default Save Settings Codabar On Default Codabar Off Save Settings Codablock F On Codablock F Off Default Save Settings ...

Page 17: ... Code 11 Checksum 1 digit Strip from result Code 11 Checksum 2 digit Strip from result Save Settings Code 39 On Default Code 39 Off Code 39 Enable Checksum Code 39 Enable Checksum Strip from result Disable Checksum Default Code 39 Extended Full ASCII On Code 39 Extended Full ASCII Off Default Code 39 Short Margin On Code 39 Short Margin Off Default Code 39 Trioptic On Default Code 39 Trioptic Off ...

Page 18: ... handheld 7 1 6 Code 93 Example 7 1 7 Code 128 Example 7 1 8 Composite Code 39 On Default Code 93 Off Save Settings Code 128 On Default Code 128 Off Code 128 Short Margin On Code 128 Short Margin Off Default Save Settings Composite On Composite Off Default Save Settings ...

Page 19: ...idimensional adaptable matrix pattern which can be reproduced practically on any surface GoCode is a private symbology and can be used by obtaining a fixed term license GoCode has many important advantages when compared with usual linear bar codes and 2D symbols Please contact Pepperl Fuchs if you require any further information on the advantages of a private symbology Data Matrix Rectangle On Dat...

Page 20: ... Maxicode Example 7 1 13 Matrix 2 of 5 Example Int 2 of 5 On Default Int 2 of 5 Off Int 2 of 5 Two Digits On Int 2 of 5 Two Digits Off Default Int 2 of 5 Four Digits On Int 2 of 5 Four Digits Off Default Save Settings Maxicode On Maxicode Off Default Save Settings Matrix 2 of 5 On Default Matrix 2 of 5 Off Save Settings ...

Page 21: ...7 1 15 MSI Plessy Example 7 1 16 NEC 2 of 5 7 1 17 PDF417 Example Micro PDF417 On Micro PDF417 Off Default Save Settings MSI Plessy On MSI Plessy Off Default Save Settings NEC 2 of 5 On NEC 2 of 5 Off Default Save Settings PDF417 On Default PDF417 Off Macro PDF 417 On Macro PDF 417 Off Default Save Settings ...

Page 22: ...codes zipcodes are deactivated as standard Scan the following codes to activate the corresponding post symbology Example Note If you wish to change the activated symbologies first scan the code Disable all Postal Codes and then the post codes for the desired symbology Australian Post On Japan Post On KIX Planet On Postnet On Planet Postnet On Royal Mail On 4 State CB On Intelligent Mail Disable al...

Page 23: ...ble Checksum Disable Checksum Default QR Code Inverse On Both Inverse and Standard On All QR On includes Micro QR Inverse QR and Micro QR On Save Settings GS1 Limited On GS1 14 and GS1 14 Truncated On GS1 14 Stacked On GS1 Expanded On All GS1 On All GS1 Off Default Save Settings Example GS1 Limited Code Example GS1 14 Truncated Code Example GS1 14 Code Example GS1 14 Stacked Code ...

Page 24: ... HD Optimizing the handheld 7 1 22 Telepen Example 7 1 23 UPC EAN JAN Example Telepen On Default Telepen Off Save Settings UPC On Default UPC Off UPC Short Margin Enabled UPC Short Margin Disabled Default UPC Extension On UPC Extension Off Save Settings ...

Page 25: ...ad high density data matrix codes scan the relevant data matrix code Scan the code Save Settings after selection Note Note the color of the illumination LEDs Please note the different data matrix codes for handhelds with white and red illumination LEDs Always scan the correct code for the relevant model Failure to do so may cause malfunctions Note Data loss All other settings are deleted when the ...

Page 26: ...nt modifications to settings Once you have adjusted all the necessary settings of the handheld you have the option of locking the settings to prevent further modifications To do so proceed as follows 1 Scan the code Reader Settings Locked 2 To unlock the handheld scan the code Reader Settings Unlocked 3 Scan the code Save Settings ...

Page 27: ...a from the handheld to the computer The data transmitted by the handheld are handled by the computer as data which have been input via a USB keyboard USB Downloader Scan this code to transmit unformatted unpacked data via the USB interface to the handheld USB Virtual COM 1 Way Mode Scan this code to port USB keyboard data to a serial application You will also need a Virtual Com driver which can be...

Page 28: ...ge the individual RS 232 connection settings RS 232 communication settings Scan the code Save Settings after selection Setting data bit 7 data bits 8 data bits default Setting stop bit 2 stop bits default 1 stop bit Setting baud rate 1200 2400 4800 9600 19200 38400 57600 Default 115200 Setting parity Even Odd None Scan this code to reset the handheld to the RS 232 default settings ...

Page 29: ...target projection Changing LED target projections To change the LED target projection scan the relevant code in the following table Scan the code Save Settings after selection Vibration mode Vibration Beep on Vibration on Beep off Vibration off Beep on Default Volume mode Beep off Beep low Beep High Default Red target LED on Red target LED off Green target LED on Green target LED off ...

Page 30: ...ate continuous operation and configure continuous reading mode scan the relevant codes in the following table Scan the code Save Settings after selection Activating Deactivating continuous operation Activating Deactivating default Reading delay Defines the time interval between the individual readings 0 seconds default 1 second 3 seconds Double code reading delay Defines the time interval during w...

Page 31: ...e code Save Settings after delection Activating continuous lighting Deactivating continuous lighting US English Keyboard No leading 0 Default US English Keyboard Leading 0 US English ctrl char for Non Printable ASCII French German Japanese Universal Keyboard Custom Keyboard Alternative OS enable Windows CE MAC Unix Linux Alternative OS disable Windows CE MAC Unix Linux ...

Page 32: ...e handheld can read codes that have been inverted Furthermore all other code reading functions are deactivated Activating Deactivating mirror decoding 1 To activate mirror decoding scan the code Mirroring on 2 Scan the mirrored code Save Settings 3 To deactivate mirror decoding scan the code Mirroring off Default 4 Scan the code Save Settings ...

Page 33: ...s also possible e g a comma followed by a space followed by the data record To define a prefix scan the corresponding data matrix code in the following table Deleting a prefix To delete all prefixes scan the data matrix code Prefix Erase Caution Risk of data loss If you scan one of the following codes data loss may result First save the settings on your handheld before scanning one of the followin...

Page 34: ...llowed by the data record Proceed as follows to define a suffix To define a suffix scan the corresponding data matrix code in the following table Deleting a suffix To delete all suffixes scan the code Suffix Erase Deleting prefixes and suffixes To delete all prefixes and suffixes scan the code Erase Prefix Suffix Data Comma as a suffix Space as a suffix Carriage return as a suffix RS 232 mode Line...

Page 35: ...ve Settings after selection 7 3 11 OCR A and B The handheld gives you the option of performing optical text identification Activating Deactivating OCR Scan one of the following codes to activate or deactivate OCR Scan the code Save Settings after selection Activate text command Deactivate text command default Activating OCR Deactivating OCR default Note You require an OCR license to use OCR functi...

Page 36: ...Microsoft Word etc 2 Scan the code Reader ID and Firmware Information on firmware and the serial numbers of the reader is transferred from the internal reader memory and displayed in the text editing program Abbreviation Character Meaning Xap i Internal ID VVVV 4 Version number of application firmware WWWW 4 Version number of bootloader firmware XXXX 4 Version number of Bluetooth firmware SSSSSSSS...

Page 37: ...d us www pepperl fuchs com Worldwide Headquarters Pepperl Fuchs GmbH Mannheim Germany E mail fa info pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg OH USA E mail fa info us pepperl fuchs com Asia Pacific Headquarters Pepperl Fuchs Pte Ltd Singapore Company Registration No 199003130E E mail fa info sg pepperl fuchs com FACTORY AUTOMATION SENSING YOUR NEEDS Contact Pepperl Fuchs GmbH...

Reviews: