![Pepperl+Fuchs OBD10M-R2000-4EP Manual Download Page 34](http://html.mh-extra.com/html/pepperl-fuchs/obd10m-r2000-4ep/obd10m-r2000-4ep_manual_1527967034.webp)
202
2-
10
34
Appendix
Indicators/operating means
Electrical specifications
Integrated application
Interface
OBD10M
OBD30M
Operation indicator
LED green
LED green
Data flow indicator
LED yellow: active eth-
ernet
LED green: Ethernet link
LED yellow: active eth-
ernet
LED green: Ethernet link
Function indicator
LED red: fault
Yellow LED: I/Q1 + I/Q2
LED red: fault
Yellow LED: I/Q1 + I/Q2
Control elements
2 Button
2 Button
Parameterization indica-
tor
24 x 252 pixels , red
24 x 252 pixels , red
OBD10M
OBD30M
Operating voltage
10 ... 30 V DC
10 ... 30 V DC
Ripple
10 % within the supply
tolerance
10 % within the supply
tolerance
No-load supply current
400 mA / 24 V DC
400 mA / 24 V DC
Protection class
III (operating voltage 50
V)
III (operating voltage 50
V)
Power consumption
< 10 W
< 10 W
Time delay before avail-
ability
< 40 s
< 40 s
Application
Field monitoring
Number of fields
4
Response time
30 ms + 1 Scan duration
Detectable object shape
Almost any
Object size
> 1 mm
Linking fields
Up to 4 x 3 levels
OBD10M
OBD30M
Interface type
4 x switching inputs/out-
puts (selectable)
4 x switching inputs/out-
puts (selectable)