![Pepperl+Fuchs LC10 Series Manual Download Page 11](http://html.mh-extra.com/html/pepperl-fuchs/lc10-series/lc10-series_manual_1527972011.webp)
2
0
1
6
-1
1
10
Manual LC10-*
Product Description
operating mode switches
The following operating modes can be set with switches 7 and 8:
3.4
Interfaces and connections
Connections LC10-1
switch 7
switch 8
result
OFF
-
Output of the loop allocation status
ON
-
Direction detection*
-
ON
Increased sensitivity (Boost)
Table 3.6
*A signal is output, depending on the allocation sequence of the loops. If loop 1 is allocated
before loop 2, only one switch signal is output for loop 1. The signal output for loop 2
remains inhibited until both loops are free again. If loop 2 is allocated before 1, only one
switch signal is output for loop 2. The signal output for loop 1 remains inhibited until both
loops are free again.
The increased sensitivity (Boost) is used for the detection of vehicles with high body
assemblies, e.g. HGVs.
Number
Explanation
Connector terminals
3
Loop connection
7/8
4
Signal output, maintained contact
5/6 = NO
6/10 = NC
5
signal output,
3/4 = NO
4/11 = NC
6
Operating voltage
1/2
7
8
6
4
1
10
5
11
3
2
4
5
6
3