Product Specifications
5
4
7
5
0
7
2
0
1
9
-0
9
13
Conformity with standards
Degree of protection
IP65 if trackball is inactive. Undefined when
moving.
Type 4X
Ambient conditions
Operating temperature
-20
°
C ... 50
°
C (-4
°
F ... 122
°
F)
Storage temperature
-20
°
C ... 70
°
C (-4
°
F ... 158
°
F)
Relative humidity
Max. 85 %, not condensing (48 h endurance
test)
Mechanical data
Material
Anodized aluminum, polyester film
Weight
1.2 kg
Dimensions
Desktop housing: 559.3 mm x 254.6 mm x
44.5 mm (22.02 x 10.02 x 1.75)
Panel mounting: 491.4 mm x 186.8 mm x 45
mm (19.35 x 7.35 x 1.77)
Opening dimensions
483 mm x 178.2 mm (19.01 x 7.01)
Cable length
1.8 m
Note
The limited energy barrier (SK-PC-D2-UU1-
10-HS) is required when using this product.
Data for use in hazardous areas
Certificate
PF II CERT 1918X
Marking
II 3GEx ic IIC T4 Gc
II 3D EX ic IIB T135
°
C Dc
Input
Voltage
U
i
5.4 VDC
Current
I
i
240 mA
Internal capacitance
C
i
24
µ
F
Internal inductance
L
i
Negligible
International approvals
UL approval
cULus (E190294)
Approved for
Class I, Division 2, Groups A, B, C, D, T5
Class II, Division 2, F,G T5