Pepperl+Fuchs DA6-IU-2K-C Operating Instructions Manual Download Page 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description 

Digital panel meter for displaying measured values, as well as monitoring limit values in industrial 

applications. 

 

 

6-digit 14-segment LED display, 14 mm, for displaying measured values and dialogs 

 

Running text can be switched on as Help Text 

 

Language for the Help Text selectable as English or German 

 

Signal input for  0 – 10 V, 2 – 10 V, ±10 V, 0 – 20 mA and 4 – 20 mA 

 

Sampling rate 10 readings per second 

 

Digital filter (1st order) for smoothing display fluctuations with unstable input signals 

 

Customised linearisation  

 

MIN/MAX memory function 

 

Totaliser function 

 

2 Relay outputs (changeover contacts) for limit monitoring 

 

Start delay for relay outputs after Power ON 

 

Versions for supply voltage 10 ... 30 V DC and 100 … 240 V AC ± 10% 

 

Auxiliary power supply 15 V DC / 25 mA 

 

Additional aux. power output 24 V / 30 mA with AC supply 

 

Programmable via the front keys 

 

Multifunction key and two multifunction inputs, function programmable 

 

Display/Operating elements 

(1) Display 

 

 

 

 

- 14 segment display, 6-digit, red 

- Height of figures 14 mm 

(2) Status display

, 2 LED annunciators , red 

- Switching status of Alarm 1 and Alarm 2 

- Indication Function Group or Function

 

(3) MP-Key and Programming Keys 

 

 

 

- Multifunction key (MP-Key)  

 

 

- Return from Function Group 

- Return from Function 

 

 

- Select previous Function Group 

- Select previous Function 

- Decrement parameter value 

 

 

- Select next Function Group 

- Select next Function 

- Increment parameter value  

 

 

- Enter a Function Group 

- Enter a Function 

- Accept the new setting 

(4) Space for unit overlay 

 

 

To enter the Programming Menu 

  +  

   > 3 sec

 

To display Device Type and Software Version  

  +  

  +  

   > 5 sec

 

To restore factory default settings 

  +  

   > 3 sec

 

 

e

n

g

li

s

h

DA6-IU-2K-V
DA6-IU-2K-C

Page 5

Summary of Contents for DA6-IU-2K-C

Page 1: ...OMATION K Operating instructions SENSING YOUR NEEDS DA6 IU 2K V DA6 IU 2K C Process Controllers for analogue input signals with Totaliser function for analogue input signals 0 10 V 2 10 V 10 10 V 0 20...

Page 2: ...l inputs 10 9 3 User Linearisation 11 9 4 Function Multifunction Key MP Key and Multifunction inputs MP INP 13 9 4 1 Multifunction Key 14 9 4 2 Multifunction Inputs 14 9 5 Totaliser function 15 9 6 Li...

Page 3: ...ication area for this device lies in industrial processes and controls in the fields of manufacturing lines for the metal wood plastics paper glass textile and other like industries Over voltages at t...

Page 4: ...inals can be found in the technical data Before starting the device check the cables for proper wiring and tightening The screws of unused screw terminals must be screwed to the stop so that they cann...

Page 5: ...0 Auxiliary power supply 15 V DC 25 mA Additional aux power output 24 V 30 mA with AC supply Programmable via the front keys Multifunction key and two multifunction inputs function programmable 4 Disp...

Page 6: ...5 Block diagram 6 Connections DA6 IU 2K V DA6 IU 2K C Page 6...

Page 7: ...7 Operating concept Operating mode english DA6 IU 2K V DA6 IU 2K C Page 7...

Page 8: ...the relays are inactive not energised When quitting the programming menu via SAVE the minimum and maximum values and the totaliser value are all cleared Entering the Programming Menu Selecting Functio...

Page 9: ...Selecting Function Setting Parameters Accepting Parameters Function Groups Function Parameter english DA6 IU 2K V DA6 IU 2K C Page 9...

Page 10: ...99999 and DP Select input high value Input range depends on meas range V mA Select display high value for INP HI Input range 199999 999999 and DP Select Input Filter The Filter function shows how many...

Page 11: ...rresponding display value DISP for this sensor value The linearisation points LP may be entered in any order They are then sorted in the firmware in ascending order for the linearisation function Line...

Page 12: ...Example for linear scaling Example 1 0 10 V 0 600 Example 2 4 20 mA 300 900 Example 3 1 0 9 0 V 750 400 Example for non linear scaling DA6 IU 2K V DA6 IU 2K C Page 12...

Page 13: ...g mode briefly activate the multifunction input 1 or multifunction input 2 Reset of relay outputs in Latch mode In the function group MP KEY programme the function RES REL to ON In the operating mode...

Page 14: ...4 2 Multifunction Inputs Menu Function MP Inputs Select function MP Input 1 No function Reset MIN value Reset MAX value Reset MIN and MAX values Reset Output Latch only if output is in memory mode AL...

Page 15: ...000 The totaliser function captures the current instantaneous measured value every 100 msec From these values the throughput rate per second is calculated To convert the throughput rate into other uni...

Page 16: ...e With alarm output inactive Select on hysteresis Input range 0 9999 and DP Select off hysteresis only with auto operation Input range 0 9999 and DP Select on delay Input range 0 0 99 9 sec Select off...

Page 17: ...Control with incrementing measuring signal Control with decrementing measuring signal english DA6 IU 2K V DA6 IU 2K C Page 17...

Page 18: ...lay Range limit Upper Display Range limit Lower Meas Range limit Upper Meas Range limit Probe or wire short circuit Probe or wire break 0 10 V 2 10 V 1 V 10 V 10 V 0 20 mA 4 20 mA 2 mA Indication blin...

Page 19: ...x104 11 5 Supply voltage AC supply 100 240 V AC max 9 VA 50 60 Hz Tolerance 10 ext fuse protection T 0 1 A DC supply 10 30 VDC max 3 5 W with galvanic isolation and reverse polarity protection SELV CL...

Page 20: ...ion 11 11 Connections Supply voltage and outputs Plug in screw terminal 8 pin RM5 00 Core cross section max 2 5 mm Signal and control inputs Plug in screw terminal 9 pin RM 3 50 Core cross section max...

Page 21: ...SPLAY START VALUE INP HI INPUT END VALUE DISP HI DISPLAY END VALUE FILTER INPUT FILTER PW DELY POWER ON DELAY FOR OUTPUTS SEC PW FREQ 50HZ POWER LINE FREQUENCY 50HZ PW FREQ 60HZ POWER LINE FREQUENCY 6...

Page 22: ...P TOT 0 0 DECIMAL POINT TOTALISER 0 0 DP TOT 0 00 DECIMAL POINT TOTALISER 0 00 DP TOT 0 000 DECIMAL POINT TOTALISER 0 000 DP TOT 0 0000 DECIMAL POINT TOTALISER 0 0000 DP TOT 0 00000 DECIMAL POINT TOTA...

Page 23: ......

Page 24: ...mbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Pacifi...

Reviews: