STEP 1
Remove the wing nut “A” located on
the inside of the fire dome.
FITTING THE DOME INTO A CEILING
f
STEP 6
Cut a 200mm diameter hole paying attention to ensure that the cut-out is
accurately made. As if it is not, the speaker may not fit correctly into the
ceiling preventing the speaker from sitting flush to the surface.
f
STEP 7
Loosen the slider knob “D”, push the knob & plate upwards to the top of the
fire dome and re-tighten the knob to hold the slider in place. Repeat the same
process with the other slider.
f
STEP 8
Push the complete fire dome into the cut-out.
f
STEP 9
Once in place loosen the slider knob “D”, push the knob & plate downwards
until the slider makes firm contact with the ceiling. Tighten the knob to secure
it into place. Repeat the same process with the other slider.
f
STEP 10
The fire dome should be firmly
secured into the ceiling.
f
STEP 11
Take the speaker and compress
one of the mounting springs &
place both ends of the spring into
one of the retaining brackets
located on the inside wall of the
fire dome. Release the spring
slowly into the bracket. Once fully
released the spring will hold one
side of the speaker into the fire
dome
.
f
STEP 12
With the speaker in this position
connect the 3 wires hanging from
the termination plate on to the
speaker using the spade terminals
provided.
f
STEP 13
Fit the second spring mount on the
speaker to the remaining bracket
on the inside of the fire dome.
Finally push the speaker into
position
.
f
STEP 14
If fitted correctly the speaker
should fit flush to the surface.
f
STEP 2
Lift the termination plate upwards & away
to separate it from the fire dome “B”.
f
STEP 3
Gland the installation cable into the termination plate using suitably rated 20mm
glands. 2 gland entries are provided for “loop in” “loop out” termination if required.
f
STEP 4
Terminate the installation cable into the terminal block on the underside of the
termination plate “C”.
f
STEP 5
Fix the termination plate back into the fire dome and secure using the wing nut
previously removed. Do not over tighten to avoid damaging the thread.
NOVEMBER 2011
RCS6/FTS
Circuit diagram 100V Common
Thermal Fuse
0.25W
0.75W
1.5W
3W
6W
ROUND METAL
CEILING
LOUDSPEAKERS
f
RCS6/FTS
INSTALLATION INSTRUCTIONS