STEP 1

Remove the wing nut “A” located on 
the inside of the fire dome.

FITTING THE DOME INTO A CEILING

f

 

STEP 6

Cut a 200mm diameter hole paying attention to ensure that the cut-out is 
accurately made. As if it is not, the speaker may not fit correctly into the 
ceiling preventing the speaker from sitting flush to the surface.

f

 

STEP 7

Loosen the slider knob “D”, push the knob & plate upwards to the top of the 
fire dome and re-tighten the knob to hold the slider in place. Repeat the same 
process with the other slider.

f

 

STEP 8

Push the complete fire dome into the cut-out.

f

 

STEP 9

Once in place loosen the slider knob “D”, push the knob & plate downwards 
until the slider makes firm contact with the ceiling. Tighten the knob to secure 
it into place. Repeat the same process with the other slider.

f

 

STEP 10

The fire dome should be firmly 
secured into the ceiling.

f

 

STEP 11

Take the speaker and compress 
one of the mounting springs & 
place both ends of the spring into 
one of the retaining brackets 
located on the inside wall of the 
fire dome. Release the spring 
slowly into the bracket. Once fully 
released the spring will hold one 
side of the speaker into the fire 
dome

f

 

STEP 12

With the speaker in this position 
connect the 3 wires hanging from 
the termination plate on to the 
speaker using the spade terminals 
provided.

f

 

STEP 13

Fit the second spring mount on the 
speaker to the remaining bracket 
on the inside of the fire dome. 
Finally push the speaker into 
position

f

 

STEP 14

If fitted correctly the speaker 
should fit flush to the surface.

f

 

STEP 2

Lift the termination plate upwards & away 
to separate it from the fire dome “B”.

f

 

STEP 3

Gland the installation cable into the termination plate using suitably rated 20mm 
glands. 2 gland entries are provided for “loop in” “loop out” termination if required.

f

 

STEP 4

Terminate the installation cable into the terminal block on the underside of the 
termination plate “C”.

 

f

 

STEP 5

Fix the termination plate back into the fire dome and secure using the wing nut 
previously removed. Do not over tighten to avoid damaging the thread.

NOVEMBER 2011

RCS6/FTS  

Circuit diagram 100V Common

Thermal Fuse

0.25W

0.75W

1.5W

3W

6W

ROUND METAL 

CEILING

LOUDSPEAKERS

f

 

RCS6/FTS

 

INSTALLATION INSTRUCTIONS