Pentek 53661 Getting Started Manual Download Page 11

Model 53661 Getting Started Guide

Page 11

Rev.  2.2

Step 4: Installing the Cabling

Connect a cable for each analog signal your application requires to the Pentek Model 
71661 XMC front panel SSMC socket receptacles on the Pentek Model 53661. These are 
labeled 

IN 1

2

3

, and 

4

: one for each ADC input channel.

The other cabling you install on the Model 53661’s front panel depends on how you 
want to handle timing and synchronization (see Timing and Synchronization). Several 
boards can be synchronized on the sync bus.

NOTE:

With Model 53661 Option 703, the front panel of the 71661 module is not 
available, as shown in the 

Model 53661 Installation Manual

. Special connection 

hardware is available for the coaxial connectors on the 71661 front panel. Call 
Pentek for further information.

Step 5: Installing the Software

ReadyFlow Software

Pentek's ReadyFlow Libraries are software packages designed to provide software 
development tools for specific Pentek products on specific operating systems or plat−
forms.  The installation procedure is different for each platform:

Linux

 − The installation steps can be summarized as follows:

Installing ReadyFlow in a Linux system

Installing WinDriver (required to run example programs)

Building the ReadyFlow example programs

Building the ReadyFlow board support libraries

For complete details, refer to Chapter 2 of the 

Model 4994A Option 166 User’s Guide

 

(816.71660).

 

Windows 

− You must install the Pentek ReadyFlow package BEFORE you attempt to boot 

the Model 53661 under Windows. The installation steps can be summarized as follows:

Installing ReadyFlow in a Windows system

Initializing the hardware (Model 53661) in Windows (responding to the New 
Hardware Wizard)

Building the ReadyFlow example programs

Building the ReadyFlow board support libraries

For complete details, refer to Chapter 2 of the 

Model 4995A Option 166 User’s Guide

 

(815.71660).

Summary of Contents for 53661

Page 1: ...0 MHz A D with four Digital Down Converters Cobalt Family VPX Board Setting the Standard for Digital Signal Processing Pentek Inc One Park Way Upper Saddle River NJ 07458 201 818 5900 www pentek com Manual Part Number 820 53661 Rev 2 2 June 12 2014 ...

Page 2: ...liminary Initial Release 3 21 11 Preliminary GateFlow FPGA Design Kit added information about the flashload utility 7 25 11 Preliminary Added battery information to What s in the Box Added 800 71601 to Documentation Required for Installation and Documentation for This Product 3 20 12 1 0 Timing and Synchronization 2 Added a note about input limit Revised for 5306 carrier 11 26 12 1 1 Added hex key...

Page 3: ...n the Pentek Model 53661 Installation Manual included in the box NOTE If your Model 53661 has Option 741 you must use a 5HP width 1 VPX slot Refer to the Model 53661 Installation Manual for details Quantity Part Number Description 1 002 53661 Model 53661 Board consisting of a Model 71661 mounted on a Model 5306 Carrier 1 002 71504 Terminator Board 1 004 71605 JTAG Board 2 385 30150 Screws for JTAG...

Page 4: ...l 800 71661 describe the operation and programming of the Pentek 71661 XMC module Before You Begin Consider the VPX Backplane The Pentek Model 5306 carrier is designed to operate in VPX systems Before installing the Model 53661 you will need to know or consider the following Is your VPX backplane connection x4 or x8 PCIe The Model 53661 offers two backplane choices Gen 1 x8 PCIe and Gen 2 x4 PCIe ...

Page 5: ...Ie clock frequency from 250 MHz the factory default to 100 MHz To preview the 71661 XMC module switch settings you ll need to consider for the Model 53661 refer to Section 2 4 of the Model 53661 Installation Manual NOTE The Model 53661 module is shipped to boot with the Gen 1 x8 PCIe default FPGA code If you want a different default see Section 2 4 2 of the Model 53661 Installation Manual Pentek M...

Page 6: ...n a set of C language routines for the Model 71661 XMC Refer to the Programmer s Reference for Models 71660 71661 and 71662 801 71660 Software for the FPGAs The FPGA is supported with a Pentek GateFlow FPGA Design Kit The GateFlow Design Kit Model 4953 Option 661 facilitates user installed FPGA functions using the Xilinx ISE Foundation tool suite The FPGA Design Kit allows the user to modify add t...

Page 7: ...during any change of frequency with the input clock signal Trigger input The front panel has one SSMC coaxial connector labeled TRIG for input of an external trigger The external trigger signal must be an LVTTL signal The trigger input can be used as a gate or trigger for A D signal processing This input is enabled using Sync Bus Control Register 2 TTL SRC bits see the Model 71660 Operating Manual...

Page 8: ...ion 105 XMC Connector The 5306 VPX carrier provides two XMC connectors designated J15 and J16 on the carrier PCB J15 provides one x4 PCI Express link between the XMC and the carrier J16 provides one x8 or two x4 serial links between the XMC and the carrier for 71661 Option 105 gigabit serial I O The 5306 VPX carrier routes these data links from the XMC J15 and J16 connectors to the VPX P1 connecto...

Page 9: ...are reserved for user defined configurations Documentation Required for Installation NOTE Some manuals are used for more than one Pentek product The manuals listed below are all used for Model 53661 Pentek Model 53661 Installation Manual 800 53661 Describes the installation and connections for the Model 53661 Pentek Model 71660 Operating Manual 800 71660 Describes the operation and programming of ...

Page 10: ...ings NOTE You should only change the jumpers or switches that are described in the Model 53661 Installation Manual all others are reserved for factory use NOTE If you need to access certain jumpers on the VPX carrier you must first remove the XMC module from the VPX carrier as described in Section 2 3 of the Model 53661 Installation Manual Step 3 Installing the Hardware The Model 53661 consists of...

Page 11: ...ek s ReadyFlow Libraries are software packages designed to provide software development tools for specific Pentek products on specific operating systems or plat forms The installation procedure is different for each platform Linux The installation steps can be summarized as follows Installing ReadyFlow in a Linux system Installing WinDriver required to run example programs Building the ReadyFlow e...

Page 12: ...G Platform Cable USB II DLC10 Xilinx part HWUSB II G The Platform USB cable connects to a USB port on your development computer system and thus carries its own 5V supply connection The other end of both cables terminates in a pod which contains a shrouded connector for a 14 pin 2 mm pitch ribbon cable The ribbon cable is included with the shipment of both Xilinx pro gramming cables To install the ...

Page 13: ...nsferring Configuration Data to the Model 71661 The GateFlow FPGA Design Kit includes test bench files and simulation projects that functionally simulate many operations of the Model 71661 when the FPGAs are con figured with their factory default configurations Details are provided in Chapter 3 of the GateFlow User Manual see Documentation Required for Installation We recommend that before attempt...

Page 14: ...ook Part No Type Description 800 53661 Installation Manual Model 53661 4 Channel 200 MHz A D with 4 DDCs Cobalt Family VPX Board 800 71660 Operating Manual Model 71660 4 Channel 200 MHz A D Cobalt Family XMC Module 800 71661 Addendum Manual Model 71661 4 Channel 200 MHz A D with 4 DDCs Cobalt Family XMC Module 800 71603 Addendum Model 716xx Reprogram FPGA from FLASH 801 71660 Programmer s Referenc...

Reviews: