![Pentair ULTRATEMP ETi 220 Installation And User Manual Download Page 21](http://html1.mh-extra.com/html/pentair/ultratemp-eti-220/ultratemp-eti-220_installation-and-user-manual_1524655021.webp)
ULTRATEMP ETI™ Hybrid Heater Installation and User’s Guide
17
Indoor Control Panel
RF Transceiver
iS4 and iS10 Spa Side Remote
IntelliChlor
IntelliFlo VF, IntelliFlo VS
QuickTouch
EasyTouch Load Center Wiring Diagram
To connect the UltraTemp ETi™ Hybrid Heater
cable to the Personality Board in the EasyTouch
Load Center:
1. Turn off the main system power before making
any connections.
2. Unlatch the front door spring latches, and open
the front door of the EasyTouch Load Center.
3. Loosen the two retaining screws from the top of
the control panel and lower the control panel down
to access the Personality Board.
4. Run a UL approved conductor cable from the
heater to the Load Center.
5. Route the cable up through the low voltage
raceway located on the left of the Load Center to
the Personality Board, see image below.
Connecting the Heater to the EasyTouch
®
Control System Load Center via the
Heater Spade Terminals
6. Insert the UltraTemp ETi cable into the gas heater
terminal connector, located on the Personality
Board.
7. Lift the control panel up into position and secure
with the two screws.
8. Connect the cable from the EasyTouch Load
Center to the heater remote control terminals
using ¼ in. (6.4 mm) “Spade” connectors, Refer to
previous page for wiring instructions.
Note:
Solar temperature sensor could be left
loose in load center. The automation system does
not use the temperature reading but just looks for
resistance.
ENGLISH