16
ThermalFlo Installation and User’s Guide
Operating the Controller
An advanced microprocessor based controller that provides a sophisticated yet simple interface to operate
your heat pump for maximum efficiency and enjoyment of your pool, controls the ThermalFlo HP heat pump.
It will control incoming water temperature between a minimum of 60º and a maximum of 104º F. The controller
also serves as system status indicator, using LED lights and error codes, see Figure 15.
During normal operation, the controller displays the temperature of the water returning to the heat pump.
Changing the desired pool or spa temperature is easily done by simply pressing the appropriate “
Up
” or
“
Down
” arrow until the display reads the desired temperature. The display returns to current water temperature
when setpoint adjustment is complete.
To display the current setpoint, simply touch the appropriate “
Up
” or “
Down
” arrow. The display will momentarily
display the current setpoint. Note that the
POOL
LED must be on to display or adjust the pool setpoint and
the
SPA
LED must be on to display or adjust the spa setpoint.
Figure 15.
Main Control Panel
WATER
PRESSURE
REMOTE
POOL
CHECK SET TEMPERATURE
PRESS ANY ARROW ONCE TO
ERROR CODES:
E01 - Low Refrigerant Pressure
E02 - High Refrigerant Pressure
E03 - Remote Error
E04 - Switch Fault
Err - Thermistor Error
LO - Water Temperature Low
HI
- Water Temperature High
SPA
POWER/
MODE
THERMOSTAT
HEATING
COOLING
AUTO- HEAT/COOL
TEMPERATURE SETTING
POOL
SPA
Summary of Contents for ThermalFlo
Page 32: ...24 ThermalFlo Installation and User s Guide ...
Page 38: ...30 ThermalFlo Installation and User s Guide Notes ...
Page 39: ...TF ...
Page 40: ...P N 473426 Rev B 3 20 06 ...