A.  An RMA # will be issued by our Product Return Department in Anoka, MN at 763-422-2211. Buyer 

should have following information available at time of RMA request:
1.  Complete Model Number, Serial Number and description of damaged unit being returned.

2.  Original Buyer Purchase Order number and date product was received by Buyer.

3.  Quantity to be returned and a brief description of failure for each unit, if different.

4.  Contact information of Buyer that must include: name of company, billing and shipping address, 

phone, number, fax number, freight carrier and the name and phone number of a Buyer contact 

who can elaborate on the claimed defect in detail.

5.  Buyer must provide a Repair Purchase Order number for both warranty and out of warranty 

repairs. The PO will not exceed 50% of a new unit. Buyer will be notified of repair charges that 

exceed approved PO amount.

B.  All returns to Pentair Equipment Protection must be securely packed, using original cartons if 

possible. All returns must have the RMA number visible on the outside of the carton. Pentair 

Equipment Protection is not responsible for material damaged in transit. Any refrigerant-bearing 

Goods must be shipped upright for return.

C.  Shipping cost for all non-warranty repairs is the responsibility of the sender and must be shipped 

prepaid. Shipping costs for all warranty related repairs will be covered by Pentair Equipment 

Protection provided the goods are returned using a Pentair Equipment Protection approved carrier. 

If after diagnoses the product is determined by Pentair Equipment Protection not be covered under 

warranty, Buyer will be responsible for all shipping charges and will be billed accordingly.

D.  Non-warranty repairs are subject to a $105 minimum analysis fee. If approval is not received within 

30 days, material will be scrapped and all shipping expenses and corresponding analysis fees will be 

billed to Buyer.

E.  At Buyer’s request, Failure Analysis can be provided by Pentair Equipment Protection for warrantable 

goods at no charge. Failure analysis for non-warranty repairs are subject to a $150 per hour 

Engineering charge plus any other incurred testing costs.

F.  All returned merchandise must be sent to the following address: Pentair Equipment Protection, 2100 

Hoffman Way, Anoka, MN 55303-1745.

G.  Credit for accepted returns shall be at the original selling price or the current selling price, whichever 

is lower, less the restocking charge indicated as follows:
1.  Within 60 days of invoice date - 20% of applicable selling price.

2.  Within 61-120 days of invoice date - 30% of applicable selling price.

3.  Within 121-180 days of invoice date - 40% of applicable selling price.

4.  Beyond 180 days - subject to individual review by Pentair Equipment Protection.
If product being returned for credit requires repair or modification, the cost of any labor or material 

necessary to bring product into saleable condition will be deducted from credit. Buyer may not take credit 

against returns without prior written Pentair Equipment Protection approval.

LIMITATION OF LIABILITY

PENTAIR EQUIPMENT PROTECTION WILL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR ANY 

INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, INCLUDING WITHOUT LIMITATION ANY LOST 

PROFITS OR LABOR COSTS, ARISING FROM THE SALE, USE OR INSTALLATION OF THE GOODS, FROM 

THE GOODS BEING INCORPORATED INTO OR BECOMING A COMPONENT OF ANOTHER PRODUCT, 

FROM ANY BREACH OF THIS AGREEMENT OR FROM ANY OTHER CAUSE WHATSOEVER, WHETHER 

BASED ON WARRANTY (EXPRESSED OR IMPLIED) OR OTHERWISE BASED ON CONTRACT, OR ON TORT 

OR OTHER THEORY OF LIABILITY, AND REGARDLESS OF ANY ADVICE OR REPRESENTATIONS THAT 

MAY HAVE BEEN RENDERED BY PENTAIR EQUIPMENT PROTECTION CONCERNING THE SALE, USE OR 

INSTALLATION OF THE GOODS.

Summary of Contents for T43

Page 1: ... 2014 Pentair Equipment Protection 89056284 Rev F P N 10 1008 145 T SERIES Air Conditioner T43 Model INSTRUCTION MANUAL ...

Page 2: ...NSIONAL DRAWINGS 4 MOUNTING CUTOUT DIMENSIONS 5 MOUNTING GASKET KIT 6 Components List 7 Wiring Diagram and Schematic 8 Generic Wire Diagram actual unit options may vary 8 Generic Schematic actual unit options may vary 9 TEMPERATURE CONTROL 10 Units With Heat 10 PRINCIPLES OF OPERATION 10 MAINTENANCE 10 Compressor 10 Inlet Air Filter 10 How To Remove Clean or Install a New Inlet Air Filter 11 Conde...

Page 3: ...ITY BEFORE MOUNTING THE AIR CONDITIONER TO THE ENCLOSURE Refer to the nameplate for proper electrical current requirements and then connect the power cord to a properly grounded power supply Minimum circuit ampacity should be at least 125 of the amperage shown in the design data section for the appropriate model No other equipment should be connected to this circuit to prevent overloading Operate ...

Page 4: ... exit point of the air conditioner The drain tube must be on a continuous downward slope A slight elevation of the tube could result in secondary trap FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN OVERFLOWING OF THE CONDENSATE DRAIN PAN 6 Refer to top of nameplate for electrical requirements Connect the power cord to a properly grounded power supply Use of an extension cord is not recommend...

Page 5: ... 2014 Pentair Equipment Protection 89056284 5 8 10K BTU MOUNTING CUTOUT DIMENSIONS External Cutout Internal Cutout ...

Page 6: ... 2014 Pentair Equipment Protection 89056284 6 MOUNTING GASKET KIT ...

Page 7: ... 6000 BTU 8000 BTU 10000 BTU 10000 BTU Capacitor CompressNor Start 10 1032 14 10 1032 08 10 1032 08 N A Capacitor Compressor Run S 6173 S 6173 52 6032 01 N A Capacitor Impeller Condenser 52 6084 02 52 6084 02 52 6084 05 52 6032 20 Capacitor Impeller Evaporator 52 6084 02 52 6084 02 52 6084 02 52 6032 44 Coil Condenser 45 6051 00 45 6051 00 45 6051 00 45 6051 00 Coil Evaporator 43 6025 00 45 6050 0...

Page 8: ... F H D76 K7 4 E7DH 57 5AD6 4 4D I F 4 G 9D 9D K7 F 7D AEF3F 8D77L7 BD7EEGD7 5A FDA B7 7D 3 4 7 F 40 7 9 6 9D 40 4 3 8 7 4 EI F5 56 46 2 4 4 56 46 AD9 I F K7 H 86 H 86 5 5AA 9 F 7D AEF3F 73F 9 F 7D AEF3F K7 4 4 4D 4 4D 2 470 4D H 86 H 86 4 I F I F I F 4 G F EI F5 7E 3GFA E 3 4 5 I F I F I F 4 G 4 4 4 4 I F 4 G 4 H 86 H 86 470 2 4 7 40 9D 7 5 AEGD7 B7 7D 4D 40 7 4 4 H I F H 4 4 G ABB EGBB AD 8800609...

Page 9: ... 2014 Pentair Equipment Protection 89056284 9 GENERIC SCHEMATIC FOR 1 PHASE MODELS ACTUAL UNIT OPTIONS MAY VARY GENERIC WIRE DIAGRAM FOR 3 PHASE MODELS ACTUAL UNIT OPTIONS MAY VARY ...

Page 10: ...sor are provided for recharging and or checking suction and discharge pressures Under no circumstances should the access fitting covers be loosened removed or tampered with Breaking of seals on compressor access fittings during warranty period will void warranty on hermetic system Recharging ports are provided for the ease and convenience of reputable refrigeration repair service personnel for rec...

Page 11: ...lter do so from both sides for maximum concentration of adhesive CONDENSER AND EVAPORATOR AIR MOVERS Impeller motors require no maintenance All bearings shafts etc are lubricated during manufacturing for the life of the motor If the condenser impeller motor ambient impeller should fail it is not necessary to remove the air conditioner from the cabinet or enclosure to replace the blower The condens...

Page 12: ...rflow Is there airflow YES proceed to step 6 NO possible problem Defective thermostat Open motor winding Stuck impeller motor Obstructed wheel Repair or Replace defective part 6 Carefully check the compressor for operation motor should cause slight vibration and the outer case of the compressor should be warm Is the compressor showing signs of this YES wait 5 minutes then proceed to step 7 NO poss...

Page 13: ...t but won t run Low line voltage at start Should be 10 rated voltage Compressor motor stuck Bad contactor Bad overload switch Bad run start capacitor Unit blows breakers Undersized breaker fuse or not time delayed Short in system Getting water in enclosure Drain plugged Drain tube kinked Enclosure not sealed allowing humidity in Mounting gasket damaged For additional technical support i e amp draw...

Page 14: ...ir Equipment Protection label affixed to product without written Pentair Equipment Protection approval Pentair Equipment Protection must be notified of a claim in writing not later than fourteen 14 days from the date when Buyer has become aware of such occurrence or where the defect is such that it may cause damage immediately such notice containing a description of how the defect manifests itself...

Page 15: ...is fee If approval is not received within 30 days material will be scrapped and all shipping expenses and corresponding analysis fees will be billed to Buyer E At Buyer s request Failure Analysis can be provided by Pentair Equipment Protection for warrantable goods at no charge Failure analysis for non warranty repairs are subject to a 150 per hour Engineering charge plus any other incurred testin...

Page 16: ... 2014 Pentair Equipment Protection 89056284 Rev F P N 10 1008 145 Pentair Equipment Protection 2100 Hoffman Way Minneapolis MN 55303 USA 1 763 422 2211 1 763 576 3200 PentairProtect com ...

Reviews: