Installer Manual Riversoft - Maintenance
Ref. MKT-IM-045 / A - 13.03.2020
69 / 90
8.5.7. Other wear and tear parts
8.5.7.1 Cleaning the backwash flow controller
No.
Operation
NOTE
The following procedure is only applicable in the bypass configuration.
A
Remove the softener cover, see 8.5.2. Covers removal (softener and valve), page 63.
B
Remove the clip (
1
).
C
Unscrew the backwash controller (
4
) by hand.
CAUTION
Pay attention to not lose the backwash controller ball (
3
) that is inside.
D
Clean the backwash controller (
4
) using a soft brush or compressed air.
E
Clean the backwash controller grooves and backwash controller chamber (
2
).
F
Reverse above procedure steps to rebuild.
NOTE
Remember to put the backwash controller ball (
3
) inside the plug when reassembling.
CAUTION
When reassembling the backwash controller (
4
), slowly screw by hand.