MAiNTENANcE
The quartz sleeve should be cleaned with warm soap and water
every three months.
UV bulb should be replaced every 9-12 months. The bulb does
not normally burn out, however the efficiency of the bulb
decreases after one year.
Contact your local water treatment professional for replacement
cartridge and bulb pricing or call 1-800-645-0267 for a dealer
near you.
leaks
At inlet/outlet connections:
• Use Plumber tape.
Between cap and housing:
• Make sure that the O-ring is clean, lubricated and
properly seated.
• Hand-tighten the housing.
• Check cartridge length. If cartridge is too long, replace
with proper length cartridge.
At UV quartz sleeve:
• Turn off all electrical power to the unit by unplugging or
throwing the circuit.
• Remove UV lamp and unscrew housing (See UV lamp
replacement).
• Check quartz sleeve for cracks, leaks and loose fittings.
• Check that O-rings between quartz sleeve and cap are
secure and have not been cut or damaged.
• If the sleeve is broken replace with a new quartz sleeve
and new O-rings.
6 •