background image

MAiNTENANcE

The quartz sleeve should be cleaned with warm soap and water 

every three months.
UV bulb should be replaced every 9-12 months. The bulb does 

not normally burn out, however the efficiency of the bulb 

decreases after one year.
Contact your local water treatment professional for replacement 

cartridge and bulb pricing or call 1-800-645-0267 for a dealer 

near you.

leaks

At inlet/outlet connections:

•  Use Plumber tape.

Between cap and housing:

•  Make sure that the O-ring is clean, lubricated and 

properly seated.

•  Hand-tighten the housing.
•  Check cartridge length. If cartridge is too long, replace 

with proper length cartridge.

At UV quartz sleeve:

•  Turn off all electrical power to the unit by unplugging or 

throwing the circuit.

•  Remove UV lamp and unscrew housing (See UV lamp 

replacement). 

•  Check quartz sleeve for cracks, leaks and loose fittings.
•   Check that O-rings between quartz sleeve and cap are 

secure and have not been cut or damaged.

•  If the sleeve is broken replace with a new quartz sleeve 

and new O-rings.

6 • 

PENTEK

®

 UV Water Systems Instruction Manual