INCOMING 115V
SINGLE PHASE
N
L1
20 AMP
BREAKER
BLK
N
WHITE
BLK
1
2
PUMP MOTOR
1 AMP
ALARM FUSE
SILENCE
SWITCH
BLUE
3
4
R
BZ
OVERLOAD PROTECTION
BUILT INTO MOTOR
R - ALARM LIGHT (RED)
BZ - ALARM BUZZER
HIGH WATER
ALARM FLOAT
4
3
1 2
G
CONNECT GROUND LUG TO
A GOOD EARTH GROUND
NOTE: CONNECT GREEN WIRES
TO GROUND LUG
HIGH
WA
TE
R
POWER CORD
BL
K
BL
K
WH
WH
CAT. NO. PA-1S
115 VOLT, 1 PHASE
WH/RED
WH/RED
WH
GRAY
R I
R I
14
13
RI
R
VIOLET
RI - SILENCE RELAY
ENCLOSURE
(21981C133A)
ALARM LIGHT
(22002A002)
CIRCUIT BREAKER
(21985A014)
WIRING
DIAGRAM
MOMENTARY PUSHBUTTON
(23330A001)
USE COPPER WIRE ONLY
GROUND LUG
(21994A001)
END SECTION (2)
(21996A000)
TERMINAL BLK. (5)
(21995A000)
BACK PANEL
(21981C134A)
RUBBER BOOT
(19773A001)
FUSE HOLDER
(21991A001)
FUSE
(20514A009)
1
AM
P. 200V
. ACC-
1
ALARM CIRCUIT FUSE
GRD
1 2 3 4
RELAY SOCKET
(23527A002)
SILENCE RELAY
(23634A005)
ALARM BUZZER
(21976A002)
23833A165 11/08/12