background image

10 cm mini

IP65 (ex : Pentair G-DECKBOX-1)

INSTALLATION IN 1.5” WALL FITTING

The following instruction describes how to install the MicroBrite light in a 1-1/2” wall fitting.

BEFORE  STARTING:  The  following  information  describes  the  tasks  that  must  be  completed  by  the 

electrician before the light wall fitting is installed. See figure below.
WARNING :

 Electrical wiring to the lighting must be in accordance with the latest edition of the Electrician 

Wiring Rules (see p1). 
The Junction Box must be installed as shown below.

The low voltage transformer (compliant with NF EN 61558-2-6) must be located in the technical room.

LIGHT INSTALLATION

Waterproof connection

15 cm extra cord

To technical room

DRY/SEALED CONDUIT INSTALLATION (USE PROVIDED KIT)

Install O-Ring then apply provided lubricant to

seal fitting and conduit from water entry

Adaptator

1-1/2” Standard Wall Fitting

4

Summary of Contents for MICROBRITE 620428

Page 1: ...UCTIONS SAVE THESE INSTRUCTIONS MICROBRITE EN WHITE LED LIGHT FOR POOL AND SPA QUICK START GUIDE Compact LED light for 1 5 pool wall fitting Download the full instructions available in EN FR NL DE IT...

Page 2: ...hygrometry 100 at 75 C Power supply 12 V 50 Hz Weight cable included 1 2 kg Consumption 12 W Light underwater use IP 68 Maximum installation depth underwater 2m Waste treatment of electronic devices...

Page 3: ...AL SHOCK OR ELECTROCUTION UNDERWATER POOL LIGHTS REQUIRE HIGH VOLTAGE WHICH CAN SHOCK BURN OR CAUSE DEATH Before working or servicing pool lights always disconnect power to the pool and or spa lights...

Page 4: ...FORMER COMPLIANT WITH NF EN 61558 2 6 Note Connect both wires to the corresponding circuit wires in the junction box brown wire to power and blue wire to common FIXED POOL AND SPA LUMINARIES SPECIFICA...

Page 5: ...ate the light installation Cut off any extra cord WARNING Electrical wiring to the lighting must be in accordance with the latest edition of the Electrician Wiring Rules see p1 3 Connect the two 2 con...

Page 6: ...w WARNING Electrical wiring to the lighting must be in accordance with the latest edition of the Electrician Wiring Rules see p1 The Junction Box must be installed as shown below The low voltage trans...

Page 7: ...cord Installation Tool Light Cable to Junction Box 1 1 2 Standard Wall Fitting Insert adaptor male thread adaptor ring into female thread of wall fitting By hand then turn light clockwise Cord will u...

Page 8: ...the 12 VAC isolation transformer and the MicroBrite Maximum wattage using multiple lights with a 300 Watt isolation transformer IMPORTANT When using multiple 12 VAC Pentair pool and spa lights the to...

Reviews: