10 cm mini
IP65 (ex : Pentair G-DECKBOX-1)
INSTALLATION IN 1.5” WALL FITTING
The following instruction describes how to install the MicroBrite light in a 1-1/2” wall fitting.
BEFORE STARTING: The following information describes the tasks that must be completed by the
electrician before the light wall fitting is installed. See figure below.
WARNING :
Electrical wiring to the lighting must be in accordance with the latest edition of the Electrician
Wiring Rules (see p1).
The Junction Box must be installed as shown below.
The low voltage transformer (compliant with NF EN 61558-2-6) must be located in the technical room.
LIGHT INSTALLATION
Waterproof connection
15 cm extra cord
To technical room
DRY/SEALED CONDUIT INSTALLATION (USE PROVIDED KIT)
Install O-Ring then apply provided lubricant to
seal fitting and conduit from water entry
Adaptator
1-1/2” Standard Wall Fitting