MagicFalls with LightCascade Technology LED Light Installation and User’s Guide
18
Verify that the pool and spa meets the requirements of the current National
Electrical Code and all local codes and ordinances. A licensed or certified
electrician must install the electrical system to meet or exceed those
requirements before the underwater light is installed. Some of the requirements
of the National Electrical Code which the pool’s electrical system must meet are
as follows:
•
The lighting circuit has a Ground Fault Circuit Interrupter (GFCI) for line
voltage models, and has an appropriately rated circuit breaker.
•
The Junction Box and the low voltage transformer is located at least 4 (four)
inches (10.16 cm) above ground level or eight (8) inches (20.3 cm) above
maximum water level, whichever is higher. The Junction Box must be at least
48 inches (1.22 m) from the edge of the pool. See Figure 1 on page 7.
•
To be certain that the pool’s electrical system meets all applicable
requirements, the electrician should also consult the local building
department.
Risk of Electrical Shock or Electrocution!
This underwater light must be installed by a licensed or certified
electrician or a qualified pool professional in accordance with
the current National Electrical Code (NEC), NFPA 70 or the
Canadian Electrical Code (CEC), CSA C22.1 and all applicable
local codes and ordinances. Improper installation will create an
electrical hazard which could result in death or serious injury to
pool users, installers or others due to electrical shock, and may
also cause damage to property.
Always disconnect the power to the pool light at the circuit
breaker before servicing the light. Failure to do so could result
in death or serious injury to service person, pool users or others
due to electrical shock.
IMPORTANT NOTICE:
THE MagicFalls LED LIGHT IS A NON-SERVICEABLE LIGHT.
THE COMPLETE LIGHT ASSEMBLY MUST BE REPLACED IF
DAMAGED, NON-OPERABLE, OR CORD IS DAMAGED.
The following removal and installation instructions describe how to remove and install the
MagicFalls LED Light assembly. Also use these instructions after completing the following
light replacement procedure. See page 19.
Failure to bring the pool or spa’s electrical system up to code
requirements before installing the light will create an electrical
hazard which could result in death or serious injury to pool users, installers, or
others due to electrical shock, and may also cause damage to property.
REPLACING THE MAGICFALLS
®
LED LIGHT ASSEMBLY